JAI Apex Series User Manual page 40

Usb3 vision interface cameras
Table of Contents

Advertisement

AP-1600T-USB | AP-3200T-USB | User Manual (Ver. 2.0)
TriggerSelector
AcquisitionTransferStart
Note: The settings for exposure control and triggers are related to each other. Be sure to
configure the settings described in
Shortest Repetition Period for Triggers
The reciprocal of the maximum frame rate is the time required to output one frame. The shortest
repetition periods for triggers cannot be lower than that value.
Scanning Range
Height BGR8 (8bit) BGR10p (10bit) BGR12p (12bit) Height BGR8 (8bit) BGR10p (10bit) BGR12p (12bit)
Full
1088
ROI (1/2)
544
ROI (1/4)
272
BinningVertical = 2
544
The above table indicates the shortest trigger periods for when Trigger OverLap is set to Readout.
When Trigger OverLap is set to Off, the exposure time is added to the period.
Output acquired images at a specified timing in response to an external trigger
signal input.
Note: There is a limit to the number of image frames that can be stored
internally. The limits for each image format are as follows.
8bit: Up to 16 frames
10bit /12bit: Up to 8 frames
"Exposure
AP-1600T-USB
12.7ms
15.9ms
6.3ms
7.9ms
3.2ms
4.0ms
6.3ms
7.9ms
Description
Mode".
19.0ms
1544
26.1ms
9.5ms
772
13.3ms
4.8ms
386
6.9ms
9.5ms
772
26.1ms
- 40 -
Main Functions
AP-3200T-USB
32.6ms
39.1ms
16.6ms
20.0ms
8.7ms
10.4ms
32.6ms
39.1ms