JAI Apex Series User Manual page 75

Usb3 vision interface cameras
Table of Contents

Advertisement

AP-1600T-USB | AP-3200T-USB | User Manual (Ver. 2.0)
Acquisition Control
Item
Trigger Source
Trigger Activation
Trigger Overlap
TriggerDelay (μs)
ExposureModeOption
Exposure Mode
Related Topic:
Exposure Mode
ExposureTimeMode
ExposureTimeSelector
Setting Range
Default
Low
High
Software
Pulse Generator
0 ~ 3
User Output 0 ~
3
Line5 - OptIn1
Line6-OptIn2
NAND0 Out
NAND1 Out
0: RisingEdge
1: FalingEdge
Rising Edge
2: LevelHigh
3: LevelLow
Off
Readout
0 ~ 500000
0
Off
Off
RCT
Off
Timed(control via
Timed
exposure time)
Trigger Width
Common
Common
Individual
Common
Red
Common
Green
Blue
Select the trigger signal source.
Default
Low (AcquisitionStart)
Low (AcquisitionEnd)
Line5 - OptIn1 (FrameStart)
Low (AcquisitionTransferStart)
Select the polarity of the trigger signal (i.e., location of signal at which
trigger is applied).
Select the trigger overlap operation. The below table shows the
default values.
Acquisition Start, Acquisition End, Acquisition Transfer
-
Off
Start
Readout
FrameStart
Set the time of exposure start from trigger input.
Set whether to enable RCT mode.
Select the exposure mode.
When set to Individual, ExposureTime can be adjusted for RGB
individually.
Selects which exposure time is controlled by the ExposureTime
feature.
- 75 -
Setting List (Feature Properties)
Description

Advertisement

Table of Contents
loading