Pulse Generators Item
Pulse Generator End
Point
Pulse Generator End
PointMS (ms)
Pulse Generator
Pulse Width (ms)
Pulse Generator
Repeat Count
Pulse Generator
Clear Activation
Pulse Generator
Clear Source
Pulse Generator
Clear Inverter
Pulse Generator
Clear Sync Mode
Setting Range
1 ~ 1048575
(1 / PulseGeneratorClock
(MHz))
~
(1048575 /
PulseGeneratorClock (MHz))
-
0 ~ 255
Off
LevelHigh
LevelLow
Rising Edge
Falling Edge
Low
High
AcquisitionTriggerWait
AcquisitionActive
FrameTriggerWait
FrameActive
ExposureActive
FVAL
LVAL
PulseGenerator0 ~ 3
UserOutput 0 ~ 3
Line5-Opt In 1
Line6-OptoIn2
Nand0Out
Nand1Out
True
False
Async Mode
Sync Mode
Default
Set the start point for the Low interval using clock value.
15000
When the counter reaches this value, the output becomes
0.
Set the start point for the Low interval using ms. When the
counter reaches this value, the output becomes 0. The
33.3333
setting range varies depending on the Clock Pre-Scaler
value.
Display High interval width for the pulse in ms. This is a
calculation of the time between the Start Point and End
33.3333
Point. The setting range varies depending on the Clock Pre-
Scaler value.
Set the repeat count for the counter. When this is set to 0,
0
the counter will be free-running with limitless repeating.
Set the clear signal condition for the count clear input of the
0: Off
pulse generator.
0: Low
Select the count clear input signal source.
Select whether to invert the polarity of the count clear input
0: False
signal.
Async Mode Select the sync mode for the count clear input signal.