Shutter Mode With Internal Trigger - JAI SW-2001Q-CL User Manual

Rgb color & nir 4ссв line scan camera
Table of Contents

Advertisement

6.2.1
No-Shutter mode with internal trigger
In this mode the camera does not accept an external trigger signal, as the line rate is generated
from an internal clock (user programmable, command LR). The exposure time is directly
proportional to the line rate (T
trigger signal is available, and the speed of the object is fixed or can be pre-determined.
The line rate can be varied from 1 line period (L) to 1024L in 1 clock (25ns) steps (19 kHz down to 18
Hz). When using this mode, a special function called "One-push auto line rate" is available. This
mode automatically maintains a constant output level by changing the line rate. The line rate is
automatically adjusted in order to maintain sensitivity without reducing the S/N ratio.
To use this mode:
Set function
Trigger mode, No-Shutter
Trigger origin, internal
Line rate
Optional functions when using this mode:
One-push auto line rate
Auto line rate reference
One-push white balance
Fig.12 No-Shutter mode with internal line rate generator
Important Note
• Only gain-based one-push white balance function (WB) is available with this mode.
SW-2001Q-CL
= 1/line rate). This mode is used when there is no external
exp
14
TR=0
TG=0
LR=2100 to 2150400
(52.5 µs to 53.8 ms in 25ns increments)
AR=0
AL=0 to 1023
WB

Advertisement

Table of Contents
loading

Table of Contents