JAI Apex Series User Manual page 51

Usb3 vision interface cameras
Table of Contents

Advertisement

AP-1600T-USB | AP-3200T-USB | User Manual (Ver. 2.0)
Manual Configuration
1. Select the index in BlemishCompensationIndex.
You can select from 1 to 200. However, configure the indexes in order starting with the smallest index. If
you skip indexes while configuring settings, interpolation may not be performed.
2. Specify the pixel points for interpolation using the BlemishCompensationPositionX and
BlemishCompensationPositionY settings. Each point is saved to the camera's internal memory as you
configure them.
You can configure values that are within the total effective pixel area. Specify pixels for which
interpolation is not necessary as -1. If 0 is specified, the first line or first pixel will be interpolated.
Note: By executing BlemishCompensationDataClear (specify sensor)
BlemishCompensationIndex, you can return a specific pixel correction setting to the default value
(storage not required).
3. Execute BlemishStore. Blemish compensation data will be stored.
4. Set BlemishEnable to True, and execute interpolation. If False is specified, defective pixel interpolation
is disabled.
- 51 -