FAN POWERED TERMINAL UNITS • 35SST SERIES
Performance Data • AHRI Certification and Performance Notes
Model Series 35SST Stealth
Fiberglass Liner
Fan Airflow
Unit
Inlet
Fan
Size
Size
Watts
cfm
l/s
2
1
6
400
189
105
71 68 64 60 57 54 62 59 52 45 41 37 400 189 0.12
2
8
700
330
155
69 67 63 62 59 57 59 57 50 45 41 37 700 330 0.08
3
10
1100
519
270
73 73 71 69 66 63 63 61 53 49 45 42 1100 519 0.03
4
12
1550
731
430
80 79 74 75 71 70 68 63 56 53 53 50 1550 731 0.05
5
14
2050
967
800
82 79 75 76 72 71 71 66 59 56 52 49 2050 967 0.04
6
14
2100
991
790
78 77 75 77 73 72 70 65 59 55 51 47 2100 991 0.06
7
16
2800
1321
760
77 74 71 70 67 66 69 65 56 53 50 46 2800 1321 0.08
Motor = ECM.
*
Primary air valve is closed and therefore primary cfm is zero.
Performance Notes for Sound Power Levels:
1. Discharge (external) static pressure is 0.25" w.g. (63 Pa) in
all cases, which is the difference (∆Ps) in static pressure
from terminal discharge to the room.
Discharge Sound Power Levels (SWL) now include
duct end reflection energy as part of the standard
rating. Including the duct end correction provides sound
power levels that would normally be transmitted into an
acoustically, non-reflective duct. The effect of including
the energy correction to the discharge SWL, is higher
sound power levels when compared to previous AHRI
certified data. For more information on duct end reflection
calculations see AHRI Standard 880.
2. Radiated sound power is the breakout noise transmitted
through the unit casing walls.
3. Sound power levels are in decibels, dB re 10
• Series Flow • AHRI Certification Rating Points
Fan Only* @ .25" w.g. (62 Pa) ∆Ps
Discharge
Radiated
3
4
5
6
7
2
3
4
5
6
watts.
-12
Fan + 100% Primary @ 1.5" w.g. (375 Pa)
Min. Inlet
Primary
∆Ps w/ .25" w.g. (62 Pa) Discharge ∆Ps
Airflow
∆Ps
7 cfm l/s "w.g. Pa
2
30
64
19
67
7
64
12
72
10
72
15
73
19
72
Ratings are certified in
accordance with AHRI
Standards.
4. All sound data listed by octave bands is raw data without
any corrections for room absorption or duct attenuation.
Dash (-) in space indicates sound power level is less than
20 dB or equal to background.
5. Min. inlet ∆Ps is the minimum operating pressure of the
primary air valve section.
6. Asterisk (*) in space indicates that the minimum inlet static
pressure requirement is greater than 0.5" w.g. (125 Pa) at
rated airflow.
7. Data derived from independent tests conducted in
accordance with ANSI / ASHRAE Standard 130 and AHRI
Standard 880.
Radiated
3
4
5
6
7
62
54
47
45
44
63
55
49
45
45
64
56
53
49
48
68
62
58
54
53
68
62
57
54
52
69
62
57
54
53
66
61
55
51
49
C
C75

Advertisement

Table of Contents
loading

This manual is also suitable for:

35s35se

Table of Contents