Nailor 35SW Manual page 19

Fan powered terminal unit with epic ecm motor
Table of Contents

Advertisement

Model 35SXC • Basic Unit
MULTI-POINT
FLOW SENSOR
DIA. =
NOM. –
1/8" (3)
STANDARD FEATURES:
• 18 ga. (1.31) galvanized steel
channel frame with 20 ga. (1.00)
casing components.
• 16 ga. (1.61) galvanized steel
inclined opposed blade damper.
45° rotation. CW to close.
• Multi-point averaging Diamond
Flow
sensor.
Supplied
balancing tees.
• Full size access panels on 3
sides.
• Steri-liner insulation. 13/16"
(21) thick, 4 lb./sq. ft. (64 kg/m
density rigid fiberglass with alum.
FSK facing. Meets requirements
of NFPA 90A and UL 181.
• Stealth XC tuned inlet silencer.
Perforated galvanized steel liner
with fiberglass acoustic media.
• Single
point
electrical
connection.
• Discharge opening for flanged
duct connection.
• Full primary air valve low voltage
NEMA 1 type enclosure for factory
mounted DDC controls.
• Controls mounted as standard
on RH side as shown. Terminals
ordered with LH controls (optional)
are inverted and discharge duct
hanging elevation will therefore
change.
• Ultra-high
efficiency
ECM
fan motor. EPIC fan volume
controller.
OPTIONS:
Digital Controls:
q
Factory mounted (supplied by
others)
q
Field mounted (supplied by
others)
SCHEDULE TYPE:
PROJECT:
ENGINEER:
CONTRACTOR:
Nailor Industries Inc. reserves the right to change any information concerning product or pricing without notice.
FAN POWERED TERMINAL UNIT W/ EPIC ECM MOTOR
STEALTH XC • SERIES FLOW • SUPER QUIET
EXPOSED CEILING APPLICATIONS
VARIABLE VOLUME FAN OPERATION
MODELS: 35SXC, 35SWXC & 35SEXC • UNIT SIZES 1, 3 & 5
W
2
PRIMARY
AIR
5 3/4"
(146)
14" (356)
DRIVESHAFT
5 1/2"
(140)
OPTIONAL
PRIMARY
PRIMARY
with
AIR VALVE
CONTROLS
AIR
H
ENCLOSURE
2
3
)
Dimensional Data
Unit
Inlet
Size
Size
4, 5, 6, 8
1
(102, 127, 152, 203)
6, 8, 10, 12
3
(125, 203, 254, 305)
10, 12, 14
5
(254, 305, 356)
Terminal Liner:
q
Steri-liner
q
Steri-liner + Perforated metal
Silencer Liner:
q
Fiberglass acoustic media
q
Steri-Liner/Polymer film
Other:
q
Left-hand controls location
q
Toggle disconnect switch
q
Fan unit fusing
q
24/24V Isolation transformer
q
Cross Flow Sensor
q
1" (25) Throwaway filter
L
FAN
HINGED FAN
CONTROLS ENCLOSURE
5 3/4"
(146)
OPTIONAL
90° FN2
CONTROLS
ENCLOSURE
6 3/4"
(171)
14" (356)
HINGED FAN
11"
CONTROLS
(279)
ENCLOSURE
W
W2
H
L
B
20
41
14
36
(508)
(1041)
(356)
(914)
(152)
26
47
18
41
(660)
(1194)
(457)
(1041)
(178)
26
53
20
55
(660)
(1346)
(508)
(1397)
(178)
q
2" (51) Filter rack only
q
Hanger brackets
q
1/4-turn fasteners (access
panel)
q
FN2 90° Line Voltage
Enclosure
q
FN3 Remote Line Voltage
Controls Enclosure
(See submittal FN3)
q
Dust tight enclosure seal
q
Remote user disconnect
q
Special features:
____________.
DATE
12 - 20 - 23
1" (25)
IH
INDUCED
AIR
OPTIONAL
INDUCED
AIR FILTER
DH
1" (25)
15"
(381)
H -
H
1" (25)
Induced Air
Outlet
Inlet
Discharge
IW x IH
DW x DH
6
6 x 14
8 1/8 x 4 1/4
(152 x 356)
(206 x 108)
7
6 x 18
9 1/8 x 10 1/2
(152 x 457)
(232 x 267)
7
12 x 20
13 1/8 x 15 5/8
(305 x 508)
(333 x 397)
Electrical Data
EPIC ECM Motor FLA
Unit
Motor
Size
120V 208V 240V 277V
HP
2.1
*
1
4.8
*
3
10.5
*
5
The ECM is a variable horsepower motor.
*
Refer to Selectworks schedule for actual
power consumption.
FLA = Full load amperage. All motors are
single phase/60 Hz.
Page 1 of 2.
For heat options; see page 2.
Dimensions are in inches (mm).
B SERIES
SUPERSEDES DRAWING NO.
3500
11 - 4 - 22
IW
B
W2
DW
W
Filter
Size
6 x 14
(152 x 356)
6 x 18
(152 x 457)
12 x 20
(305 x 508)
1.4
1.3
1.2
3.4
3.1
3.0
6.8
6.4
6.2
35SXC-1

Advertisement

Table of Contents
loading

This manual is also suitable for:

35s35se

Table of Contents