Nailor 35SW Manual page 25

Fan powered terminal unit with epic ecm motor
Table of Contents

Advertisement

A Solid metal liner completely isolates the standard insulation and its raw edges from the airstream within the terminal.
The solid metal liner option, also referred to as double wall construction, offers excellent protection against exposure of
fiberglass particles to the airstream. This option is ideal for applications where Indoor Air Quality (IAQ) is a concern and
where terminals will be wiped down and cleaned on a regular basis. This option is also resistant to moisture.
ISOLATED INSULATION
Material:
Thickness:
Density:
Thermal Conductance: 0.36 BTU / hr-ft
(C)
STANDARD AND CODE COMPLIANCE
• UL 181 Class I
• ASTM E84 and UL 723 Flame/Smoke (25/50)
• NFPA 90A and 90B
• ASTM C 1071 Air Velocity (2000 fpm max.)
• ASTM C 665
ACOUSTICAL PERFORMANCE
Correction factors to cataloged sound power level data (standard dual density insulation) are shown below.
Single Duct Terminal Units • 3000 Series Basic Unit • All sizes.
Octave Band
Center Frequency (Hz) 125
Discharge Sound
Radiated Sound
Fan Powered Terminal Units • 33SZ, 35N, 35S, 37N and 37S Series • All sizes.
Octave Band
Center Frequency (Hz) 125
Discharge Sound
Radiated Sound
Fan Powered Terminal Units • 35SST and 37SST "Stealth" Series • All sizes.
Octave Band
Center Frequency (Hz) 125
Discharge Sound
Radiated Sound
Dual Duct Terminal Units • 3230 and 3240 "Blendmaster" Series • All sizes.
Nailor has independently tested and cataloged their dual duct sound data based upon the use of Steri-Liner (high
density foil back insulation) rather than standard dual density fiberglass insulation as used in the above terminal units.
This is because it is the most popular specification for dual duct terminals, where IAQ is frequently a concern. Solid
metal liner is acoustically reflective in a manner similar to Steri-Liner. The cataloged data may therefore be used
without correction when a solid metal liner is required.
SCHEDULE TYPE
PROJECT
ENGINEER
CONTRACTOR
Nailor Industries Inc. reserves the right to change any information concerning product or pricing without notice.
VAV TERMINAL UNITS
LINER OPTIONS
TYPE: SOLID METAL LINER
Dual Density flame attenuated glass fiber.
3/4" (19). (37N, 37S, 37SST and 33SZ Size 30 Low Profile Fan Powered Terminal Units use
1/2" (13) material).
4.0 lb/cu. ft. (64 kg/m
) skin.
3
1.5 lb/cu. ft. (24 kg/m
3
) core.
2
-°F @ 75°F (2.04 W / m
For 1/2" (13) material: 0.52 BTU / hr-ft
2
3
250
0
0
-1
-2
2
3
250
0
0
+2
+1
2
3
250
0
0
-5
-4
(DOUBLE WALL CONSTRUCTION)
2
-°C @ 24°C).
2
-°F @ 75°F (2.95 W / m
4
5
500
1000
2000
0
0
-2
-3
4
5
500
1000
2000
0
0
+2
+6
+13
4
5
500
1000
2000
0
0
-4
0
DATE
8 - 19 - 16
2
-°C @ 24°C).
6
7
NC Impact
4000
(Average)
0
0
-3
-3
6
7
NC Impact
4000
(Average)
0
0
+14
+3
6
7
NC Impact
4000
(Average)
0
0
+3
+5
B SERIES
SUPERSEDES DRAWING NO.
VAV.ACC.
11 - 19 - 12
0
-2
0
0
-4
VAV - SML

Advertisement

Table of Contents
loading

This manual is also suitable for:

35s35se