4.1 Matching to the cable length

The cable length is limited to 20m because of the transmission method used
between the rotor and the stator. If you are using a long connecting cable, you
must match the stator electronics. There are three switches in the stator
housing for this. The switches are accessible when the name-plate is
removed.
Switches
Fig. 4.1: Switches in the stator housing
Switch
vertical
arrangement
position
1
2
3
Please ensure that after switching to switch position 3, the calibration signal is
not initiated.
1) The switches may be positioned vertically or horizontally depending on manufacture.
horizontal
1)
1)
arrangement
a) Older amplifiers
b) For when the calibration signal is
unintentionally initiated with very short cable
Normal position (ex-works position)
For cable lengths over 20 m