Electrical Connection Stator B - HBM T10F Mounting Instructions

Torque flange
Hide thumbs Also See for T10F:
Table of Contents

Advertisement

24
5

Electrical connection stator B

Stator B has the identifying order number K--T10F... (see page 35). The stator
housing has several 7--pin Binder 723 device plugs which are assigned in ac-
cordance with the option selected.
The supply voltage and the calibration signal of plugs 1 and 3 are direct--
coupled via multifuses (automatically resetting fuses).
Assignment for plug 1:
Voltage supply and frequency output signal.
6
6
1
1
5
5
7
7
2
2
4
4
3
3
1)
Factory setting
If the frequency--output voltage is shifted symmetrically to 5V, connection ca-
ble Kab 139A--6 cannot be used (pin 5 is not assigned). In this event the as-
signment of the Kab 139--6 cable has to be changed, or the connection has to
be made using series 423 cable plugs, order number 3--3101.0247.
NOTE
In the case of symmetrical output, use twisted pairs of stranded wire. If
lines exceed 50m in length, terminating resistors must be provided (de-
pending on cable capacity).
Assignment for plug 3:
Voltage supply and voltage output signal.
6
6
1
1
5
5
7
7
2
2
4
4
3
3
1
Measuring signal torque (frequency output; 0V;
2
Supply voltage 0V;
3
Supply voltage 18V ... 30V
4
Measuring signal torque (frequency output; 12V
5
Measuring signal 0V;
6
Calibration signal 5V ... 30V
7
Calibration signal 0V;
Screen on housing ground
1
Measuring signal torque (voltage output; 0V
2
Supply voltage 0V;
3
Supply voltage 18V ... 30V
4
Mesuring signal torque, voltage output, +10V
5
Not used
6
Calibration signal 5V ... 30V
7
Calibration signal 0V;
Screen on housing ground
symmetrical
T10F
1)
/--5V)<WH>
<BK>
<BU>
1)
/+5V) <RD>
<GN>
<GY>
)
<WH>
<BK>
<BU>
<RD>
<GN>
<GY>

Advertisement

Table of Contents
loading

Table of Contents