Mechanical installation

WARNING
Handle the torque flange carefully. The transducer might suffer
permanent damage from mechanical shock (dropping), chemical effects
(e.g. acids, solvants) or thermal effects (hot air, steam).
Do in no case slacken the screwed rotor joints marked with sealing
varnish (the hexagon-socket screws for measuring body/adapter flange
and the type plate's slotted screws).
With alternating loads, you should use a screw locking device (medium)
to glue the rotor connnection-screws into the counter thread to exclude
a pretension loss due to screw slackening.
An appropriate shaft flange enables the T10F Torque Flanges to be mounted
directly. The adapter flange enables direct mounting of a cardan shaft or
corresponding corrector elements (if necessary, via intermediate flange). Do in
no case exceed the permissible limits specified for bending moments,
transverse and longitudinal forces. Due to the T10F Torque Flanges' high
torsional stiffness, dynamic changes on the shafting are minimized.
CAUTION
Do in any case check the effect on critical speeds and natural torsional
vibrations to avoid an overloading of the torque flanges due to
resonance step-up.
NOTE
For regular operation do in any case observe the mounting dimensions
(see page 34).