Installing Protectors - HBM T10F Mounting Instructions

Torque flange
Hide thumbs Also See for T10F:
Table of Contents

Advertisement

18
4. Install the two antenna segments' upper connection screw such that the
antenna ring is closed. Also pay attention to the fan
5. Now, fasten all antenna
5Nm.
6. Align antenna and rotor such that the antenna encloses the rotor about
coaxially. Please observe the permissible alignment tolerances specified in
the technical data.
7. Fasten the stator
8. Make sure that the opening in the lower antenna
section is free from electroconductive foreign substances.
CAUTION
In order to ensure proper functioning, the serrated locking washers (A5,
1-EST Din 6796 ZN/Blau Pass.) must be renewed after the antenna
screws have been loosened three times.

3.6 Installing protectors

DANGER
According to the prevailing regulation to prevent accidents a cover has
to be fitted after the mounting of the torque transducers T10F as follows:
Ÿ the cover must be stationary
Ÿ the cover shall avoid any danger of squeezing and provide protection
against parts that might come loose
Ÿ the cover shall be installed at a minimum distance from moving parts
or shall be of a nature that a hand cannot be put through
Ÿ the cover shall be fitted even if moving parts are installed outside the
usual access area of persons.
Above regulations could only be disregarded if there is already sufficient
protection of machine parts owing to the design of the machine or due to other
precautions.
segment screwings with a tightening torque of
-
housing screwed connection.
-
type lock washers.
-
segment
-