Panasonic HEVC Advance AW-UE160WP Operating Instructions Manual page 170

4k integrated camera
Hide thumbs Also See for HEVC Advance AW-UE160WP:
Table of Contents

Advertisement

Web screen configurations (continued)
IPv6 network
Manual [On, Off]
Enable or disable manual configuration of the IPv6 address.
On
Enter the IPv6 address manually.
Off
Disable manual entry of the IPv6 address.
Factory settings: Off
IP address(IPv6)
When [Manual] is set to [On], the IPv6 address must be entered
manually.
Be sure to enter an address unique from other devices.
<NOTE>
• When connecting to the manually specified IP address through a
router, use an IPv6-compatible router, and enable the automatic
configuration function for the IPv6 address. Be sure to configure
an IPv6 address that includes the prefix information provided
by the IPv6-compatible router. For details, refer to the operating
instructions for the router.
• Link local address cannot be set.
Default gateway
When [Manual] is set to [On] for [IPv6 network], enter the default
gateway for the unit's IPv6 network.
Factory settings: blank
<NOTE>
• It is not possible to set the default gateway when [DHCPv6] is [On].
DHCPv6 [On, Off]
Enable or disable use of the IPv6 DHCP function.
Configure the DHCP server so that the same IP address is not
configured for a personal computer that does not use the DHCP
function and other network cameras. For details on server settings,
consult your network administrator.
On
Use the IPv6 DHCP function.
Off
Do not use the IPv6 DHCP function.
Factory settings: Off
Metric [100 to 110]
Set the LAN interface priority for this unit.
Packets are output with priority to the interface with the lower number
compared to the value set in [SFP+]/[USB].
Factory settings: 100
z SFP+
<NOTE>
• This cannot be set when the [Basic Config]-[SFP+ Mode] is
[12G Output].
IPv4 network
DHCP [On, Off]
Select the method for setting the IP address.
Factory settings: Off
<NOTE>
• When [DHCP] has been set to [On], it is not possible to use the
automatic IP address setting (AUTO IP) from AW-RP150 or
AW-RP60.
IP address(IPv4)
When not using the DHCP function, enter the unit's IP address.
Enter so that the address does not duplicate the IP addresses of the
personal computer or other network cameras.
Factory settings: 192.168.0.10
<NOTE>
• Even when using the DHCP function, it is not possible to use
multiple IP addresses. Consult the network administrator regarding
the settings for the DHCP server.
Subnet mask
When not using the DHCP function, enter the unit's subnet mask.
Factory settings: 255.255.255.0
Default gateway
When not using the DHCP function, enter the unit's default gateway.
Factory settings: 192.168.0.1
<NOTE>
• Even when using the DHCP function, it is not possible to use
multiple IP addresses with the default gateway.
Consult the network administrator regarding the settings for the
DHCP server.
Metric [100 to 110]
Set the SFP+ interface priority for this unit.
Packets are output with priority to the interface with the lower number
compared to the value set in [LAN]/[USB].
Factory settings: 103
z USB
IPv4 network
DHCP [On]
Select the method for setting the IP address.
Factory settings: Off
<NOTE>
• When [DHCP] has been set to [On], it is not possible to use the
automatic IP address setting (AUTO IP) from AW-RP150 or AW-
RP60.
170

Advertisement

Table of Contents
loading

Table of Contents