Web screen configurations (continued)
Pan/Tilt settings screen [Pan/Tilt]
The setting is confirmed with the [Set] button.
Install Position [Desktop, Hanging]
[Desktop] or [Hanging] is selected here as the method used to install
the unit.
Desktop
Stand-alone installation
Hanging
Suspended installation
Factory settings: Desktop
<NOTE>
• When [Hanging] has been selected, the top, bottom, left and right
of the images will be reversed, and up/down/left/right control for
panning and tilting will also be reversed.
Smart Picture Flip
Mode [Off, Auto]
When the tilt becomes the angle set for [Flip Detect Angle], the image
will be flipped in the vertical direction automatically.
Off
The picture is not turned upside down.
Auto
The picture is automatically turned upside down.
Factory settings: Off
Flip Detect Angle [60deg to 120deg]
Set the tilt angle at which the image will be flipped in the vertical
direction automatically when [Smart Picture Flip] is set to [Auto].
Factory settings: 90deg
P/T Speed Mode
[Normal(60deg/s), Fast1(90deg/s), Fast2(180deg/s)]
Set the speed of pan/tilt operation.
Normal(60deg/s)
Pan/tilt operates at normal speed (maximum about
60° per second).
Fast1(90deg/s)
Pan/tilt operates at fast speed1 (maximum about
90° per second).
Fast2(180deg/s)
Pan/tilt operates at fast speed2 (maximum about
180° per second).
Factory settings: Normal(60deg/s)
P/T Acceleration Setting
Displays the advanced setting screen for setting the
accelerationspeed while starting/stopping a pan/tilt operation.
P/T Acceleration [Manual, Auto]
Sets whether to perform advance setting for acceleration and
deceleration etc. during manual operation of pan/tilt.
Manual
Sets the advanced settings for acceleration speed
etc. during start/stop or changing the speed of pan/tilt
operation.
Auto
Sets the settings for automatic acceleration and
deceleration speed etc. during start/stop or changing the
speed of pan/tilt operations.
Factory settings: Auto
Rise S-Curve [0 to 30]
Sets the S-curve for pan/tilt acceleration operation in 31 steps. (The
greater the number, the steeper the S-curve)
When it is necessary to increase the speed to the specified speed
using manual control of pan/tilt by lever operation etc. through the
controller, the acceleration process is performed based on the
S-curve specified in this setting.
This is enabled only when [P/T Acceleration] is [Manual].
Factory settings: 15
<NOTE>
• In order to limit the acceleration response, in the S-curve step, as
the acceleration speed rises, the limit is automatically applied.
Fall S-Curve [0 to 30]
Sets the S-curve for pan/tilt deceleration operation in 31 steps. (The
greater the number, the steeper the S-curve)
When it is necessary to reduce the speed to the specified speed
using manual control of pan/tilt by lever operation etc. through the
controller, the deceleration process is performed based on the
S-curve specified in this setting.
This is enabled only when [P/T Acceleration] is [Manual].
Factory settings: 15
<NOTE>
• In order to limit the deceleration response, in the S-curve step, as
the deceleration speed rises, the limit is automatically applied.
Rise Acceleration [1 to 255]
Sets the acceleration speed for pan/tilt acceleration operation
in 255 steps. (The acceleration speed increases as the number
increases.)
When it is necessary to increase the speed to the specified speed
using manual control of pan/tilt by lever operation etc. through the
controller, the acceleration process is performed based on the
acceleration speed specified in this setting.
This is enabled only when [P/T Acceleration] is [Manual].
Factory settings: 128
<NOTE>
• When the specified acceleration speed is small, it is not possible
to reach the maximum speed of the product.