SET COMMUNICATION:

This section define the fundamental communication parameters of two buses, EtherNet/IP and NMEA
2000.
By Pressing the
"Set
Communication" button from the main window for SW67589 (Fig. 2) the window
"Set Communication" appears (Fig. 3).
The window is divided in two sections, one for the EtherNet/IP and the other for the NMEA 2000.
The means of the fields for "EtherNet/IP" are:
In the fields "IP" insert the IP address that you want to give to the Converter;
In the fields
"SubNet
Mask" insert the SubNet Mask;
In the fields
"Default
Gateway" insert the default gateway that you want to use. This feature
can be enabled of disabled pressing the Check Box field;
In the field "Port" insert the number of port;
In the field
"Number Byte
defined (at maximum it is possible to use 500 byte);
In the field
"Number Byte
defined (at maximum it is possible to use 500 byte).
The means of the fields for the "NMEA 2000" section are:
In the field
"Baud
rate" the baudrate for the NMEA2000 is defined;
In the field
"TimeOut
Data" insert a time, when this time is elapsed the data of NMEA 2000
framewil be cancel;
If the field
"Peer to
Peer" is checked the gateway accept any ID that have the PGN inserted in the section "Receive NMEA;
ADFweb.com Srl – IT31010 – Mareno – Treviso
IN" the number of byte from the EtherNet/IP to the Converter is
OUT" the number of byte from the Converter to the EtherNet/IP is
User Manual EtherNet/IP / NMEA 2000
Document code: MN67589_ENG
Revision 1.002