ADF Web HD67507-A1 User Manual

ADF Web HD67507-A1 User Manual

Modbus tcp slave / modbus master - converter
Hide thumbs Also See for HD67507-A1:

Advertisement

Industrial Electronic Devices
User Manual
Revision 2.200
English
Modbus TCP Slave / Modbus Master - Converter
(Order Code: HD67507-A1, HD67507-A1-422, HD67507-B2,
HD67507-WiFi-B2-232, HD67507-WiFi-B2-485)
for Website information:
www.adfweb.com?Product=HD67507
for Price information:
www.adfweb.com?Price=HD67507-A1
www.adfweb.com?Price=HD67507-B2
www.adfweb.com?Price=HD67507-WiFi-B2-232
www.adfweb.com?Price=HD67507-WiFi-B2-485
Benefits and Main Features:
Very easy to configure
32mm Rail DIN mount
Wide supply input range
Galvanic Isolation
Temperature range: -40°C/+85°C (-40°F/+185°F)
User Manual
ADFweb.com S.r.l.
User Manual Modbus TCP Slave / Modbus Master
Document code: MN67507_ENG
For others products, see also the following links:
RS232 / RS485 / USB / Ethernet
www.adfweb.com?Product=HD67118
www.adfweb.com?Product=HD67119
www.adfweb.com?Product=HD67038
CAN / CANopen / Modbus / Modbus TCP
www.adfweb.com?Product=HD67001
www.adfweb.com?Product=HD67502
www.adfweb.com?Product=HD67011
www.adfweb.com?Product=HD67012
www.adfweb.com?Product=HD67514
www.adfweb.com?Product=HD67515
Modbus RTU Slave / Modbus TCP Master - Converter
www.adfweb.com?Product=HD67510
Do you have your customer protocol? Then go to:
www.adfweb.com?Product=HD67003
Do you need to choose a device? Do you want help?
www.adfweb.com?Cmd=helpme
Revision 2.200
Page 1 of 38
(RS232 / RS485 - Converter)
(USB / RS485 - Converter)
(RS485 / RS232 / Ethernet - Converter)
(CANopen / Modbus Master - Converter)
(CANopen / Modbus Slave - Converter)
(CAN / Modbus Master - Converter)
(CAN / Modbus Slave - Converter)
(CAN / Modbus TCP Master – Converter)
(CAN / Modbus TCP Slave – Converter)

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the HD67507-A1 and is the answer not in the manual?

Questions and answers

Summary of Contents for ADF Web HD67507-A1

  • Page 1 Document code: MN67507_ENG Revision 2.200 Page 1 of 38 Industrial Electronic Devices User Manual Revision 2.200 English Modbus TCP Slave / Modbus Master - Converter (Order Code: HD67507-A1, HD67507-A1-422, HD67507-B2, HD67507-WiFi-B2-232, HD67507-WiFi-B2-485) for Website information: www.adfweb.com?Product=HD67507 for Price information: www.adfweb.com?Price=HD67507-A1 www.adfweb.com?Price=HD67507-B2 www.adfweb.com?Price=HD67507-WiFi-B2-232 For others products, see also the following links: www.adfweb.com?Price=HD67507-WiFi-B2-485...
  • Page 2: Updated Documentation

    With this “Document Code” go to web page www.adfweb.com/download/ and search for the corresponding code on the page. Click on the proper “Document CHARACTERISTICS Code” and download the updates. POWER SUPPLY FUNCTION MODES LEDS (for HD67507-A1 and HD67507-B2) REVISION LIST: LEDS (for HD67507-WiFi-B2) ETHERNET Revision Date...
  • Page 3: Security Alert

    User Manual Modbus TCP Slave / Modbus Master Document code: MN67507_ENG Revision 2.200 Page 3 of 38 Industrial Electronic Devices SECURITY ALERT: ENERAL NFORMATION To ensure safe operation, the device must be operated according to the instructions in the manual. When using the device are required for each individual application, legal and safety regulation.
  • Page 4: Examples Of Connection

    User Manual Modbus TCP Slave / Modbus Master Document code: MN67507_ENG Revision 2.200 Page 4 of 38 Industrial Electronic Devices EXAMPLES OF CONNECTION: ADFweb.com S.r.l.
  • Page 5 User Manual Modbus TCP Slave / Modbus Master Document code: MN67507_ENG Revision 2.200 Page 5 of 38 Industrial Electronic Devices ADFweb.com S.r.l.
  • Page 6: Connection Scheme

    User Manual Modbus TCP Slave / Modbus Master Document code: MN67507_ENG Revision 2.200 Page 6 of 38 Industrial Electronic Devices CONNECTION SCHEME: Figure 1a: Connection scheme for HD67507-A1 ADFweb.com S.r.l.
  • Page 7 User Manual Modbus TCP Slave / Modbus Master Document code: MN67507_ENG Revision 2.200 Page 7 of 38 Industrial Electronic Devices Figure 1b: Connection scheme for HD67507-A1-422 ADFweb.com S.r.l.
  • Page 8 User Manual Modbus TCP Slave / Modbus Master Document code: MN67507_ENG Revision 2.200 Page 8 of 38 Industrial Electronic Devices Figure 1c: Connection scheme for HD67507-B2 ADFweb.com S.r.l.
  • Page 9 User Manual Modbus TCP Slave / Modbus Master Document code: MN67507_ENG Revision 2.200 Page 9 of 38 Industrial Electronic Devices Figure 1d: Connection scheme for HD67507-WiFi-B2-232 ADFweb.com S.r.l.
  • Page 10 User Manual Modbus TCP Slave / Modbus Master Document code: MN67507_ENG Revision 2.200 Page 10 of 38 Industrial Electronic Devices Figure 1e: Connection scheme for HD67507-WiFi-B2-485 ADFweb.com S.r.l.
  • Page 11 Wide power supply input range: 8…24V AC or 12…35V DC; Wide temperature range: -40°C / 85°C [-40°F / +185°F]. This HD67507-A1/B2 is able to manage a maximum of ten simultaneous connections from Ethernet side. It can be used in two operative ways: In the “Routing Mode”...
  • Page 12: Power Supply

    The devices can be powered at 8…24V AC and 12…35V DC. For more details see the two tables below. Vmin Vmax Vmin Vmax Consumption at 24V DC: Device Consumption [W/VA] HD67507-A1 HD67507-A1-422 HD67507-B2 HD67507-WiFi-B2-xxx Caution: Not reverse the polarity power HD67507-B2 HD67507-A1 HD67507-A1-422 HD67507-WiFi-B2 ADFweb.com S.r.l.
  • Page 13: Function Modes

    User Manual Modbus TCP Slave / Modbus Master Document code: MN67507_ENG Revision 2.200 Page 13 of 38 Industrial Electronic Devices FUNCTION MODES: The device has got two function modes depending on the position of the ‘Dip2 of Dip-Switch A’: The first, with ‘Dip2 of Dip-Switch A’ at “OFF” position, is used for the normal working of the device. The second, with ‘Dip2 of Dip-Switch A’...
  • Page 14 Page 14 of 38 Industrial Electronic Devices LEDS (for HD67507-A1 and HD67507-B2): The devices has got four (five for HD67507-B2) LEDs that are used to give information of the functioning status. The various meanings of the LEDs are described in the table below.
  • Page 15 User Manual Modbus TCP Slave / Modbus Master Document code: MN67507_ENG Revision 2.200 Page 15 of 38 Industrial Electronic Devices LEDS (for HD67507-WiFi-B2): The devices has got five LEDs that are used to give information of the functioning status. The various meanings of the LEDs are described in the table below. Normal Mode Boot Mode Blinks quickly: Boot state...
  • Page 16 User Manual Modbus TCP Slave / Modbus Master Document code: MN67507_ENG Revision 2.200 Page 16 of 38 Industrial Electronic Devices ETHERNET: The Ethernet connection must be made using Connector5 of HD67507 with at least a Category 5E cable. The maximum length of the cable should not exceed 100m.
  • Page 17 It is recommended that the RS232 cable not exceed 15 meters. The HD67507-A1/B2 is provided with a D-sub connector type DE-9 Male (also called DB-9). The cable must use a DE-9 Female connector. The serial port is used for programming the device and for Modbus communication.
  • Page 18 User Manual Modbus TCP Slave / Modbus Master Document code: MN67507_ENG Revision 2.200 Page 18 of 38 Industrial Electronic Devices RS485: To terminate the RS485 line with a 120Ω resistor, it is necessary to put dip 1 ON, like in figure. Ù...
  • Page 19 User Manual Modbus TCP Slave / Modbus Master Document code: MN67507_ENG Revision 2.200 Page 19 of 38 Industrial Electronic Devices The maximum length of the cable should be 1200m (4000 feet). Here some codes of cables: Belden: p/n 8132 - 2x 28AWG stranded twisted pairs conductor + foil shield + braid shield; Belden p/n 82842 - 2x 24AWG stranded twisted pairs conductor + foil shield + braid shield;...
  • Page 20 User Manual Modbus TCP Slave / Modbus Master Document code: MN67507_ENG Revision 2.200 Page 20 of 38 Industrial Electronic Devices USE OF COMPOSITOR SW67507: To configure the Converter, use the available software that runs with Windows called SW67507. It is downloadable on the site www.adfweb.com and its operation is described in this document.
  • Page 21: New Configuration / Open Configuration

    User Manual Modbus TCP Slave / Modbus Master Document code: MN67507_ENG Revision 2.200 Page 21 of 38 Industrial Electronic Devices NEW CONFIGURATION / OPEN CONFIGURATION: “New Configuration” button creates the folder which contains the entire device’s configuration. A device’s configuration can also be imported or exported: To clone the configurations of a programmable “Modbus TCP Slave / Modbus Master - Converter”...
  • Page 22: Software Options

    User Manual Modbus TCP Slave / Modbus Master Document code: MN67507_ENG Revision 2.200 Page 22 of 38 Industrial Electronic Devices SOFTWARE OPTIONS: By pressing the “Settings” ( ) button there is the possibility to change the language of the software and check the updatings for the compositor.
  • Page 23: Set Communication

    “NAT Mode” (see the description at page 27). If selected “HD67507-A1 / B2” the means of the fields for “Modbus TCP Slave” are: In the field “IP Address” the IP address of Modbus TCP side of the converter is defined;...
  • Page 24 User Manual Modbus TCP Slave / Modbus Master Document code: MN67507_ENG Revision 2.200 Page 24 of 38 Industrial Electronic Devices If the field “Fast StartUp (only 100Mb/s)” is checked, the Converter take less time to go online. This command can use only if the Converter is used in a 100Mb/s network;...
  • Page 25 User Manual Modbus TCP Slave / Modbus Master Document code: MN67507_ENG Revision 2.200 Page 25 of 38 Industrial Electronic Devices If selected “HD67507-WiFi-B2”, it is possible to defined the type of Wi-Fi communication: Access Point; Client. The means of the fields for “Modbus TCP Slave on Wi-Fi” for Access Point configuration are: In the field “IP Address”...
  • Page 26 User Manual Modbus TCP Slave / Modbus Master Document code: MN67507_ENG Revision 2.200 Page 26 of 38 Industrial Electronic Devices The means of the fields for “Modbus TCP Slave on Wi-Fi” for Client configuration are: If the field “Obtain an IP Address automatically”...
  • Page 27: Operation Mode

    User Manual Modbus TCP Slave / Modbus Master Document code: MN67507_ENG Revision 2.200 Page 27 of 38 Industrial Electronic Devices OPERATION MODE: OUTING A few characteristics of the Modbus RTU package have been modified in the standard of the Modbus TCP protocol. Two bytes of the final CRC were eliminated (no longer necessary for the information to reach its already corrected destination).
  • Page 28: Translate Table

    User Manual Modbus TCP Slave / Modbus Master Document code: MN67507_ENG Revision 2.200 Page 28 of 38 Industrial Electronic Devices TRANSLATE TABLE: Within the section “Translate Table” it is possible to define the variables that can be read or written by the TCP bus on the RTU bus when the device is in NAT mode.
  • Page 29 User Manual Modbus TCP Slave / Modbus Master Document code: MN67507_ENG Revision 2.200 Page 29 of 38 Industrial Electronic Devices Example 1: If you want, from TCP network, write a data it the RTU network on the device at: Address 5; Through Gateway WORD 100 (Address RTU);...
  • Page 30 User Manual Modbus TCP Slave / Modbus Master Document code: MN67507_ENG Revision 2.200 Page 30 of 38 Industrial Electronic Devices UPDATE VIA SERIAL (only for hardware versions with jumpers): By pressing the “Update Via USB” button it is possible to load the created Configuration into the device, and also the Firmware if is necessary, using the RS232 port.
  • Page 31: Update Via Udp

    User Manual Modbus TCP Slave / Modbus Master Document code: MN67507_ENG Revision 2.200 Page 31 of 38 Industrial Electronic Devices UPDATE VIA UDP: By pressing the “Update Device” button, it is possible to load the created Configuration into the device; and also the Firmware, if necessary. If you don’t know the actual IP address of the device you have to use this procedure: Turn OFF the Device;...
  • Page 32 User Manual Modbus TCP Slave / Modbus Master Document code: MN67507_ENG Revision 2.200 Page 32 of 38 Industrial Electronic Devices Note: When you install a new version of the software, if it is the first time it is better you do the update of the Firmware in the HD67507 device.
  • Page 33: Mechanical Dimensions

    User Manual Modbus TCP Slave / Modbus Master Document code: MN67507_ENG Revision 2.200 Page 33 of 38 Industrial Electronic Devices MECHANICAL DIMENSIONS: Figure 8a: Mechanical dimensions scheme for HD67507-A1 Figure 8b: Mechanical dimensions scheme for HD67507-A1-422 ADFweb.com S.r.l.
  • Page 34 User Manual Modbus TCP Slave / Modbus Master Document code: MN67507_ENG Revision 2.200 Page 34 of 38 Industrial Electronic Devices Figure 8c: Mechanical dimensions scheme for HD67507-B2 Figure 8d: Mechanical dimensions scheme for HD67507-WiFi-B2-xxx ADFweb.com S.r.l.
  • Page 35: Ordering Informations

    The ordering part number is formed by a valid combination of the following: HD67507 - xxxx – xx - xxx Serial port: None: RS232 + RS485 (only for HD67507-A1 and HD67507-B2) 232: RS232 (only for HD67507-WiFi-B2-xxx) 485: RS485 (only for HD67507-WiFi-B2-xxx)
  • Page 36 Document code: MN67507_ENG Revision 2.200 Page 36 of 38 Industrial Electronic Devices Order Code: HD67507-A1 Modbus TCP Slave / Modbus Master – Converter ( Modbus TCP: Ethernet - Modbus RTU: RS232 or RS485 ) Order Code: HD67507-A1-422 Modbus TCP Slave / Modbus Master – Converter...
  • Page 37 User Manual Modbus TCP Slave / Modbus Master Document code: MN67507_ENG Revision 2.200 Page 37 of 38 Industrial Electronic Devices DISCLAIMER: All technical content within this document can be modified without notice. The content of the document is a under continual renewal. For losses due to fire, earthquake, third party access or other accidents, or intentional or accidental abuse, misuse, or use under abnormal conditions repairs are charged to the user.
  • Page 38: Warranties And Technical Support

    User Manual Modbus TCP Slave / Modbus Master Document code: MN67507_ENG Revision 2.200 Page 38 of 38 Industrial Electronic Devices WARRANTIES AND TECHNICAL SUPPORT: For fast and easy technical support for your ADFweb.com SRL products, consult our internet support at www.adfweb.com. Otherwise contact us at the address support@adfweb.com RETURN POLICY: If while using your product you have any problem and you wish to exchange or repair it, please do the following:...

Table of Contents