ADF Web AXIS HD67597-A1 User Manual

ADF Web AXIS HD67597-A1 User Manual

Ethernet/ip / devicenet master - converter
Hide thumbs Also See for AXIS HD67597-A1:

Advertisement

Quick Links

Industrial Electronic Devices
User Manual
Revision 1.011
English
EtherNet/IP / DeviceNet Master -
Converter
(Order Code: HD67597-A1)
for Website information:
www.adfweb.com?Product=HD67597
for Price information:
www.adfweb.com?Price=HD67597-A1
Benefits and Main Features:
Very easy to configure
Two Ethernet/IP ports
Temperature range: -40°C/85°C (-40°F/185°F)
ADFweb.com Srl – IT31010 – Mareno – Treviso
User Manual EtherNet/IP / DeviceNet Master - Converter
Other
Products
Axis Solutions Pvt Ltd is the Authorized Distributor of
Axis Solutions Pvt Ltd is the Authorized Distributor of
Axis Solutions Pvt Ltd is the Authorized Distributor of
Axis Solutions Pvt Ltd is the Authorized Distributor of
www.axisindia.in | info@axisindia.in
www.axisindia.in | info@axisindia.in
www.axisindia.in | info@axisindia.in
www.axisindia.in | info@axisindia.in
Document code: MN67597_ENG
Revision 1.011
For others Ethernet/IP products see also the following link:
Converter Ethernet/IP to
www.adfweb.com?Product=HD67077
www.adfweb.com?Product=HD67595
www.adfweb.com?Product=HD67598
www.adfweb.com?Product=HD67599
www.adfweb.com?Product=HD67589
www.adfweb.com?Product=HD67590
www.adfweb.com?Product=HD67590
www.adfweb.com?Product=HD67591
www.adfweb.com?Product=HD67591
www.adfweb.com?Product=HD67592
www.adfweb.com?Product=HD67592
Do you have an your customer protocol?
www.adfweb.com?Product=HD67003
Do you need to choose a device? do you want help?
www.adfweb.com?Cmd=helpme
INFO:
www.adfweb.com
in India
in India
in India
in India
Pagina 1 di 25
(M-Bus)
(CAN)
(DeviceNet Slave)
(J1939)
(NMEA2000)
(Serial RS232)
(Serial RS485)
(Modbus Master RS232)
(Modbus Master RS485)
(Modbus Slave RS232)
(Modbus Slave RS485)
Phone +39.0438.30.91.31

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AXIS HD67597-A1 and is the answer not in the manual?

Questions and answers

Summary of Contents for ADF Web AXIS HD67597-A1

  • Page 1 User Manual EtherNet/IP / DeviceNet Master - Converter Document code: MN67597_ENG Revision 1.011 Pagina 1 di 25 Industrial Electronic Devices User Manual Revision 1.011 English EtherNet/IP / DeviceNet Master - Converter (Order Code: HD67597-A1) for Website information: www.adfweb.com?Product=HD67597 for Price information: www.adfweb.com?Price=HD67597-A1 Benefits and Main Features: Very easy to configure...
  • Page 2: Updated Documentation

    User Manual EtherNet/IP / DeviceNet Master - Converter Document code: MN67597_ENG Revision 1.011 Pagina 2 di 25 Industrial Electronic Devices INDEX: UPDATED DOCUMENTATION: Dear customer, we thank you for your attention and we remind you that you need to check that the following document is: Page Updated INDEX...
  • Page 3: Security Alert

    User Manual EtherNet/IP / DeviceNet Master - Converter Document code: MN67597_ENG Revision 1.011 Pagina 3 di 25 Industrial Electronic Devices SECURITY ALERT: ENERAL NFORMATION To ensure safe operation, the device must be operated according to the instructions in the manual. When using the device are required for each individual application, legal and safety regulation.
  • Page 4: Example Of Connection

    User Manual EtherNet/IP / DeviceNet Master - Converter Document code: MN67597_ENG Revision 1.011 Pagina 4 di 25 Industrial Electronic Devices EXAMPLE OF CONNECTION: ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com Phone +39.0438.30.91.31...
  • Page 5: Connection Scheme

    User Manual EtherNet/IP / DeviceNet Master - Converter Document code: MN67597_ENG Revision 1.011 Pagina 5 di 25 Industrial Electronic Devices CONNECTION SCHEME: Figure 1: Connection scheme for HD67597-A1 ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com Phone +39.0438.30.91.31...
  • Page 6 User Manual EtherNet/IP / DeviceNet Master - Converter Document code: MN67597_ENG Revision 1.011 Pagina 6 di 25 Industrial Electronic Devices CHARACTERISTICS: The HD67597-A1 is a EtherNet/IP / DeviceNet Master Converter. It allows the following characteristics: Up to 500 bytes in reading and 500 bytes in writing; Two-directional information between CAN bus and EtherNet/IP bus;...
  • Page 7: Power Supply

    User Manual EtherNet/IP / DeviceNet Master - Converter Document code: MN67597_ENG Revision 1.011 Pagina 7 di 25 Industrial Electronic Devices POWER SUPPLY: The devices can be powered at 8…24V AC and 12…35V DC. For more details see the two tables below. Vmin Vmax Vmin...
  • Page 8: Function Modes

    User Manual EtherNet/IP / DeviceNet Master - Converter Document code: MN67597_ENG Revision 1.011 Pagina 8 di 25 Industrial Electronic Devices FUNCTION MODES: The device has got two functions mode depending of the position of the ‘Dip2 of Dip-Switch A’: The first, with ‘Dip2 of Dip-Switch A’ at “OFF” position, is used for the normal working of the device. The second, with ‘Dip2 of Dip-Switch A’...
  • Page 9 User Manual EtherNet/IP / DeviceNet Master - Converter Document code: MN67597_ENG Revision 1.011 Pagina 9 di 25 Industrial Electronic Devices LEDS: The device has got four LEDs that are used to give information of the functioning status. The various meanings of the LEDs are described in the table below. Normal Mode Boot Mode Blinks quickly: Boot state...
  • Page 10 User Manual EtherNet/IP / DeviceNet Master - Converter Document code: MN67597_ENG Revision 1.011 Pagina 10 di 25 Industrial Electronic Devices ETHERNET/IP: The EtherNet/IP connection must be made using Connector3 and/or Connector4 of HD67597-A1 with at least a Category 5E cable. The maximum length of the cable should not exceed 100m.
  • Page 11 User Manual EtherNet/IP / DeviceNet Master - Converter Document code: MN67597_ENG Revision 1.011 Pagina 11 di 25 Industrial Electronic Devices DeviceNet: For terminate the CAN line with a 120Ω resistor it is necessary that the Dip1 of ‘Dip-Switch B’ is at ON position. Cable characteristics: DC parameter: Impedance...
  • Page 12: New Project / Open Project

    User Manual EtherNet/IP / DeviceNet Master - Converter Document code: MN67597_ENG Revision 1.011 Pagina 12 di 25 Industrial Electronic Devices USE OF COMPOSITOR SW67597: To configure the Converter, use the available software that runs with Windows, called SW67597. downloadable site www.adfweb.com and its operation is described in this document.
  • Page 13: Set Communication

    User Manual EtherNet/IP / DeviceNet Master - Converter Document code: MN67597_ENG Revision 1.011 Pagina 13 di 25 Industrial Electronic Devices SET COMMUNICATION: This section define the fundamental communication parameters of two buses, EtherNet/IP and DeviceNet. By Pressing the “Set Communication” button from the main window for SW67597 (Fig. 2) the window “Set Communication”...
  • Page 14: Devicenet Network

    User Manual EtherNet/IP / DeviceNet Master - Converter Document code: MN67597_ENG Revision 1.011 Pagina 14 di 25 Industrial Electronic Devices DEVICENET NETWORK: By pressing the “DeviceNet Network” button from the main window for SW67597 (Fig. 2) the window “DeviceNet Network” appears (Fig. The data of the columns have the following meanings: In the field “ID”...
  • Page 15 User Manual EtherNet/IP / DeviceNet Master - Converter Document code: MN67597_ENG Revision 1.011 Pagina 15 di 25 Industrial Electronic Devices DEFINE BYTE: By pressing the “Define Byte” button from the main window for SW67597 (Fig. 2) the window “Define Offset” appears (Fig. 5). In the field “Select the Slave DeviceNet”...
  • Page 16: Update Device

    User Manual EtherNet/IP / DeviceNet Master - Converter Document code: MN67597_ENG Revision 1.011 Pagina 16 di 25 Industrial Electronic Devices UPDATE DEVICE: By pressing the “Update Device” button it is possible to load the created Configuration into the device; and also the Firmware, if is necessary.
  • Page 17 User Manual EtherNet/IP / DeviceNet Master - Converter Document code: MN67597_ENG Revision 1.011 Pagina 17 di 25 Industrial Electronic Devices If you know the actual IP address of the device you have to use this procedure: Turn on the Device with the Ethernet cable inserted; Insert the actual IP of the Converter;...
  • Page 18: Mechanical Dimensions

    User Manual EtherNet/IP / DeviceNet Master - Converter Document code: MN67597_ENG Revision 1.011 Pagina 18 di 25 Industrial Electronic Devices MECHANICAL DIMENSIONS: Figure 8: Mechanical dimensions scheme for HD67597-A1 ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com Phone +39.0438.30.91.31...
  • Page 19: Ordering Informations

    User Manual EtherNet/IP / DeviceNet Master - Converter Document code: MN67597_ENG Revision 1.011 Pagina 19 di 25 Industrial Electronic Devices ORDERING INFORMATIONS: The ordering part number is formed by a valid combination of the following: HD67597 – A 1 Connectors Type 1: Removable 5mm Screw Terminal Enclosure Type A: 1M, 35mm DIN Rail mounting...
  • Page 20: Plc Configuration

    User Manual EtherNet/IP / DeviceNet Master - Converter Document code: MN67597_ENG Revision 1.011 Pagina 20 di 25 Industrial Electronic Devices PLC CONFIGURATION: The configuration and commissioning of the EtherNet/IP Converter as described on the following pages was accomplished with the help of the “RSLogix 5000”...
  • Page 21 User Manual EtherNet/IP / DeviceNet Master - Converter Document code: MN67597_ENG Revision 1.011 Pagina 21 di 25 Industrial Electronic Devices 2) Edit the settings of the new Generic Ethernet Module. As shown in the screen shot below, the module was named “HD67597” and the IP-address assigned is 192.168.0.5. For the Comm Format “Data –...
  • Page 22 User Manual EtherNet/IP / DeviceNet Master - Converter Document code: MN67597_ENG Revision 1.011 Pagina 22 di 25 Industrial Electronic Devices 4) After the configuration is completed, the controller tags are created. ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com Phone +39.0438.30.91.31...
  • Page 23 User Manual EtherNet/IP / DeviceNet Master - Converter Document code: MN67597_ENG Revision 1.011 Pagina 23 di 25 Industrial Electronic Devices 5) With “RSLinks Classic Lite”, after have done a network scan (RSWho), and finding the EtherNet/IP device, it is possible to load the EDS file for the device in order to have the “Module Info”...
  • Page 24: Other Regulations And Standards

    User Manual EtherNet/IP / DeviceNet Master - Converter Document code: MN67597_ENG Revision 1.011 Pagina 24 di 25 Industrial Electronic Devices DISCLAIMER All technical content within this document can be modified without notice. The content of the document content is a recurring audit. For losses due to fire, earthquake, third party access or other accidents, or intentional or accidental abuse, misuse, or use under abnormal conditions repairs are charged to the user.
  • Page 25: Warranties And Technical Support

    User Manual EtherNet/IP / DeviceNet Master - Converter Document code: MN67597_ENG Revision 1.011 Pagina 25 di 25 Industrial Electronic Devices WARRANTIES AND TECHNICAL SUPPORT: For fast and easy technical support for your ADFweb.com SRL products, consult our internet support at www.adfweb.com. Otherwise contact us at the address support@adfweb.com RETURN POLICY: If while using your product you have any problem and you wish to exchange or repair it, please do the following:...

Table of Contents