Psu Energy Efficiency - Teldat M2 Series Installation Manual

Edge router
Hide thumbs Also See for M2 Series:
Table of Contents

Advertisement

Teldat
Network Standby: 6W
Individual interfaces on the Teldat M2 can also be shut down independently. To learn how to disable each interface,
please refer to the configuration manuals. For more information, please see the "Teldat Dm772-I Configuration Inter-
faces" manual.

4.7 PSU energy efficiency

As per Commission Regulation (EU) 2019/1782, which establishes ecodesign requirements for external power sup-
plies in accordance with Directive 2009/125/EC of the European Parliament and Council, and revokes Commission
Regulation (EC) No 278/2009, the instruction manuals for end-users must contain the following information:
TLDP00F1 and TLDP01F1 models.
Model
Manufacturer Name
Manufacturer Address
Input Voltage
Input AC frequency
Output voltage
Output current
Output power
Average active efficiency
Efficiency at low load (10%)
No-load power consumption
TLDP02F1 and TLDP03F1 models.
Model
Manufacturer Name
Manufacturer Address
Input Voltage
Input AC frequency
Output voltage
Output current
Output power
Average active efficiency
Efficiency at low load (10%)
No-load power consumption
Teldat M2/M2L
WA-30P12R
ASIAN POWER DEVICES INC. (APD)
NO.5 LANE 83. LUNG-SOU ST, TAO-YUAN CITY, TAIWAN R.O.C.
100-240 Vac
50-60 Hz
12.0 V
2.5 A
30.0 W
87.7 %
77.7 %
Lower than 0.075 W
WA-36N12R
ASIAN POWER DEVICES INC. (APD)
NO.5 LANE 83. LUNG-SOU ST, TAO-YUAN CITY, TAIWAN R.O.C.
100-240 Vac
50-60 Hz
12.0 V
3.0 A
36.0 W
87.403 %
78.3 %
Lower than 0.1 W
4 Compliance