Checking the Server Air Flow

The control panel LEDs display system heat status. See "Control Panel" in Chapter 1 for
details.
Make sure there are no objects to obstruct airflow in and out of the server.
Use only recommended server parts.
Make sure no wires or foreign objects obstruct air flow through the chassis. Pull all excess
cabling out of the airflow path or use shorter cables.

Overheating

There are several possible responses if the system overheats.
Use the LEDs to determine the nature of the overheating condition.
Confirm that the chassis cover is installed properly.
Make sure all fans are present and operating normally.
Check the routing of the cables.
Verify that the heatsinks are installed properly.
Chapter 3: Maintenance and Component Installation