Summary of Contents for Supermicro SuperServer SYS-530MT-H8TNR

  • Page 1 SuperServer ® SYS-530MT-H8TNR USER’S MANUAL Revision 1.0...
  • Page 2 State of California, USA. The State of California, County of Santa Clara shall be the exclusive venue for the resolution of any such disputes. Supermicro's total liability for all claims will not exceed the price paid for the hardware product.
  • Page 3 If you have any questions, please contact our support team at: support@supermicro.com This manual may be periodically updated without notice. Please check the Supermicro website for possible updates to the manual revision level. Secure Data Deletion A secure data deletion tool designed to fully erase all data from storage devices can be found on our website: https://www.supermicro.com/about/policies/disclaimer.cfm?url=/wdl/utility/...
  • Page 4: Table Of Contents

    Preface Contents Chapter 1 Introduction 1.1 Overview ..........................8 1.2 System Features ........................9 Control Panel .........................10 Rear View ..........................11 Connecting to a Node ....................12 Node Trays ........................13 1.3 System Architecture ......................14 Main Components ......................14 1.4 Motherboard Layout ......................15 Quick Reference Table ......................16 Motherboard Block Diagram .....................17 1.5 Where to Get Replacement Components ................18 1.6 Returning Merchandise for Service ..................18...
  • Page 5 Preface Chapter 3 Maintenance and Component Installation 3.1 Removing Power .......................28 3.2 Accessing the System ......................29 Removing a Computing Node ..................29 Removing the Chassis Cover ...................30 3.3 Processor and Heatsink .....................31 Prepare the System ......................31 ESD Precautions .......................31 Installing the LGA1200 Processor ..................32 Installing a Passive CPU Heatsink ...................34 Removing the CPU and the Heatsink ................35 3.4 Memory ..........................36...
  • Page 6 Preface 5.2 Driver Installation ........................60 5.3 SuperDoctor 5 ........................61 ® 5.4 BMC ............................62 BMC ADMIN User Password ....................62 Chapter 6 Troubleshooting and Support 6.1 Information Resources .......................63 Website ..........................63 Direct Links for the SYS-530MT-H8TNR System ............63 Direct Links for General Support and Information ............63 6.2 BMC Interface ........................64 6.3 Troubleshooting Procedures .....................65 No Power ..........................65...
  • Page 7 Super Micro Computer, Inc. 980 Rock Ave. San Jose, CA 95131 U.S.A. Tel: +1 (408) 503-8000 Fax: +1 (408) 503-8008 Email: marketing@supermicro.com (General Information) support@supermicro.com (Technical Support) Website: www.supermicro.com Europe Address: Super Micro Computer B.V. Het Sterrenbeeld 28, 5215 ML...
  • Page 8: Chapter 1 Introduction

    3U rackmount; (WxHxD) 17.26 x 5.21 x 23.2 in. (438 x 132 x 589 mm) A Quick Reference Guide can be found on the product page of the Supermicro website. The following safety models associated with the SYS-530MT-H8TNR have been certified as...
  • Page 9: System Features

    Chapter 1: Introduction 1.2 System Features The CSE-938NH-R2K04BP2 is a 3U chassis that supports 16 front hot-swappable drives and eight rear hot-pluggable nodes. Front View The chassis front offers access to the storage drives and the control panel. Control Panel Figure 1-1.
  • Page 10: Control Panel

    Chapter 1: Introduction Control Panel Power Button Power Fail Node Activity Figure 1-2. Control Panel Control Panel Features Feature Description The main power switch applies or removes primary power from the power supply to the Power Button chassis but maintains standby power. Power Fail Indicates a failed power supply module.
  • Page 11: Rear View

    Chapter 1: Introduction Rear View Dedicated and Centralized BMC LAN Ports Node 8 Node 7 Node 6 Node 5 Node 3 Node 4 Node 2 Node 1 Power Supply Power Supply Figure 1-3. System: Rear View System Features: Rear Feature Description Nodes 1-8 Each node features a power button, two LAN ports and a KVM port...
  • Page 12: Connecting To A Node

    Chapter 1: Introduction Connecting to a Node USB, COM, and VGA port capabilities can be added to any node through the KVM port on the rear. Plug in the adapter (dongle). Figure 1-5. Adapter to Provide USB, COM, and VGA Ports...
  • Page 13: Node Trays

    Chapter 1: Introduction Node Trays The chassis contains eight separate computing node drawers, each with its own motherboard. Service Tag Figure 1-6. SYS-530MT-H8TNR Node Tray BMC Password Each node supports a pull-out server tag with a unique BMC Password Label. Extend the server tag and use the unique password to log into the BMC as the ADMIN user.
  • Page 14: System Architecture

    Chapter 1: Introduction 1.3 System Architecture This section highlights the features on the node. Main Components PCIe 4.0 x8 (in x16) LP PCIe 4.0 x8 (in x16) LP Slot Slot 2 RJ45 GbE LAN Port 2 RJ45 GbE LAN Port (MicroLP Module) (MicroLP Module) 2 SATA3 M.2 Slots...
  • Page 15: Motherboard Layout

    Chapter 1: Introduction 1.4 Motherboard Layout Below is a layout of the X12STD-F motherboard with jumper, connector and LED locations shown. See the table on the following page for descriptions. For detailed descriptions, pinout information and jumper settings, refer to Chapter 4 or the Motherboard Manual.
  • Page 16: Quick Reference Table

    Chapter 1: Introduction Quick Reference Table Jumper Description Default Setting Pins 1-2: Onboard PCH SATA SATA/SAS Select Pins 2-3: AOC SAS JBM1 Disable BMC Share LAN Pins 1-1 (Enabled) JBT1 CMOS Clear Open (Normal) JPG1 VGA Enable/Disable Pins 1-2 (Enabled) JPME2 Manufacturing Mode Pins 1-2 (Normal)
  • Page 17: Motherboard Block Diagram

    Chapter 1: Introduction Motherboard Block Diagram 3200 MT/s support is limited to 1R1R configurations. (64GB) Up to 128GB ECC UDIMM (2933MT/s) PCIe4.0_x8 PCIe x8 MLP SLOT INTEL LGA1200 DDR4 (CHB) 16.0GT/s DIMMA1 DIMMA2 3200MHz/2933MHz 2 HDD PORTS PCIe4.0_x8 PCIe x8 SLOT (open end) NVMe/SAS/SATA 16.0GT/s DDR4 (CHB)
  • Page 18: Where To Get Replacement Components

    (http://www.supermicro.com/ support/rma/). Whenever possible, repack the chassis in the original Supermicro carton, using the original packaging material. If these are no longer available, be sure to pack the chassis securely, using packaging material to surround the chassis so that it does not shift within the carton and become damaged during shipping.
  • Page 19: Chapter 2 Server Installation

    Chapter 2: Server Installation Chapter 2 Server Installation 2.1 Overview This chapter provides advice and instructions for mounting your system in a server rack. If your system is not already fully integrated with processors, system memory etc., refer to Chapter 3 for details on installing those specific components.
  • Page 20: Server Precautions

    Chapter 2: Server Installation • In single rack installations, stabilizers should be attached to the rack. In multiple rack in- stallations, the racks should be coupled together. • Always make sure the rack is stable before extending a server or other component from the rack.
  • Page 21: Circuit Overloading

    Chapter 2: Server Installation Circuit Overloading Consideration should be given to the connection of the equipment to the power supply circuitry and the effect that any possible overloading of circuits might have on overcurrent protection and power supply wiring. Appropriate consideration of equipment nameplate ratings should be used when addressing this concern.
  • Page 22: Installing The Rails

    Chapter 2: Server Installation 2.3 Installing the Rails There are a variety of rack units on the market, which may require a slightly different assembly procedure. This rail set fits a rack between 26.8" and 36.4" deep. The following is a basic guideline for installing the system into a rack with the rack mounting hardware provided.
  • Page 23: Releasing The Inner Rail

    Chapter 2: Server Installation Releasing the Inner Rail Each inner rail has a locking latch. This latch prevents the server from coming completely out of the rack when the chassis is pulled out for servicing. To mount the rail onto the chassis, first release the inner rail from the outer rails. 1.
  • Page 24: Installing The Inner Rails On The Chassis

    Chapter 2: Server Installation Installing the Inner Rails on the Chassis Installing the Inner Rails 1. Identify the left and right inner rails. They are labeled. 2. Place the inner rail firmly against the side of the chassis, aligning the hooks on the side of the chassis with the holes in the inner rail.
  • Page 25: Installing The Outer Rails Onto The Rack

    Chapter 2: Server Installation Installing the Outer Rails onto the Rack Each end of the assembled outer rail includes a bracket with hooks and square, spring-loaded pegs to fit into the square holes in your rack. Installing the Outer Rail 1.
  • Page 26: Installing The Chassis Into A Rack

    Chapter 2: Server Installation 2.4 Installing the Chassis into a Rack Once rails are attached to the chassis and the rack, you can install the server. Warning: Mounting the system into the rack requires at least two people to support the chassis during installation.
  • Page 27: Removing The Chassis From The Rack

    Chapter 2: Server Installation Removing the Chassis from the Rack Caution! The system is heavy. It is dangerous for a single person to remove it from the rack. Have sufficient personnel or use a lift to support the chassis. 1. Pull the chassis forward out the front of the rack until it stops. 2.
  • Page 28: Chapter 3 Maintenance And Component Installation

    Chapter 3: Maintenance and Component Installation Chapter 3 Maintenance and Component Installation This chapter provides instructions on installing and replacing main system components. To prevent compatibility issues, only use components that match the specifications and/or part numbers given. Installation or replacement of most components require that power first be removed from the system.
  • Page 29: Accessing The System

    Chapter 3: Maintenance and Component Installation 3.2 Accessing the System The chassis contains eight computing nodes, each removable from the rear of the chassis while the others continue operating. Removing a Computing Node The two storage drives controlled by the node will power down upon removal. 1.
  • Page 30: Removing The Chassis Cover

    Chapter 3: Maintenance and Component Installation Removing the Chassis Cover You can access some chassis components, such as fans, by removing the cover. Screws Figure 3-2. Removing the Chassis Cover Removing the Chassis Cover The chassis top cover can be lifted off after removing three screws. Caution: Except for short periods of time, do not operate the server without the cover in place.
  • Page 31: Processor And Heatsink

    3. Check that the plastic protective cover is on the CPU socket and that none of the socket pins are bent. If they are, contact your retailer. 4. Refer to the Supermicro website for updates on processor and memory support. Note: All graphics in this manual are for illustration only. Your components may look different.
  • Page 32: Installing The Lga1200 Processor

    Chapter 3: Maintenance and Component Installation Installing the LGA1200 Processor 1. Press the load lever down to release the load plate from its locking position. Plastic Protective Cover Load Plate Load Lever 2. Gently lift the load lever to open the load plate. Remove the plastic protective cover. Do not touch the CPU socket contacts.
  • Page 33 Chapter 3: Maintenance and Component Installation 4. Carefully lower the CPU straight down into the socket. Do not drop the CPU on the socket, or move it horizontally or vertically to avoid damaging the CPU or socket. Inspect the four corners of the CPU to make sure that the CPU is properly installed. 5.
  • Page 34: Installing A Passive Cpu Heatsink

    Chapter 3: Maintenance and Component Installation Installing a Passive CPU Heatsink 1. Do not apply any thermal grease to the heatsink or the CPU die -- the required amount has already been applied. 2. Place the heatsink on top of the CPU so that the four mounting holes are aligned with those on the motherboard and the heatsink bracket underneath.
  • Page 35: Removing The Cpu And The Heatsink

    Chapter 3: Maintenance and Component Installation Removing the CPU and the Heatsink Warning: We do not recommend that the CPU or the heatsink be removed. However, if you do need to uninstall the CPU or the heatsink, please follow the instructions below to uninstall the heatsink or the CPU without damaging the CPU or the motherboard.
  • Page 36: Memory

    The X12STD-F motherboard supports up to 128GB of ECC and Non-ECC UDIMM DDR4 memory with speeds of up to 3200MHz in four memory slots. Note: Check the Supermicro website for recommended memory modules. Important: Exercise extreme care when installing or removing DIMM modules to prevent any possible damage.
  • Page 37: General Guidelines For Optimizing Memory Performance

    Chapter 3: Maintenance and Component Installation General Guidelines for Optimizing Memory Performance • The blue slots must be populated first. • It's recommended to use DDR4 memory of the same type, size, and speed. • Mixed DIMM speeds can be installed. However, all DIMMs will run at the speed of the slowest DIMM.
  • Page 38: Dimm Installation

    Chapter 3: Maintenance and Component Installation DIMM Installation JKVM1 USB3/4 JUSBP1 1. Insert DIMM modules in the following JMD2 JMD1 JTPM1 order: DIMMB2, DIMMA2, then DIMMB1, LEDM1 JPME2 DIMMA1. For the system to work properly, SRW3 SRW1 JWD1 JBM1 please use memory modules of the same SRW4 SRW2 JPCIE1...
  • Page 39: Motherboard Battery

    Chapter 3: Maintenance and Component Installation 3.5 Motherboard Battery The motherboard uses non-volatile memory to retain system information when system power is removed. This memory is powered by a lithium battery residing on the motherboard. Replacing the Battery Begin by removing the node from the system.
  • Page 40: Storage Drives

    Attention state---do not remove NVMe Amber Blinking at 1 Hz device (not supported in VMD mode) Note: Enterprise level hard disk drives are recommended for use in Supermicro chassis and servers. For information on recommended HDDs, see the Supermicro website, http://www. supermicro.com/products/nfo/files/storage/SBB-HDDCompList.pdf.
  • Page 41 Chapter 3: Maintenance and Component Installation Removing a Hot-Swap Drive Carrier from the Chassis 1. Press and slightly slide up the OPEN button at the top of the drive carrier. The drive carrier handle will extend into an open position. 2.
  • Page 42: Checking The Temperature Of An Nvme Drive

    Chapter 3: Maintenance and Component Installation Installing a Drive 1. Remove the dummy drive, which comes pre-installed in the drive carrier, by removing the screws securing the dummy drive to the carrier. These screws are not used to mount the actual drive. Dummy Drive Drive Carrier Figure 3-6.
  • Page 43: Solid State Drives

    Chapter 3: Maintenance and Component Installation M.2 Solid State Drives The motherboard supports two M.2 (M-Key) PCIe 3.0 x4 solid state drives. Slot JMD1 supports the 2280 form factor while slot JMD2 supports both the 2280 and 22110 form factors. Installing an M.2 SSD Caution: Use industry-standard anti-static equipment, such as gloves or wrist strap, and follow precautions to avoid damage caused by ESD.
  • Page 44: Pci Expansion Cards

    Chapter 3: Maintenance and Component Installation PCI Expansion Cards The system supports one low-profile PCIe card in each of the eight nodes with the included riser cards (RSC-RR1U-E16). Installing an Expansion Card 1. Power down the node and remove it. 2.
  • Page 45 Chapter 3: Maintenance and Component Installation 5. Insert the expansion card into the riser card, which is pre-installed on the motherboard (if desired, the riser card may be removed from the motherboard by removing the riser card screw). 6. Slide the add-on card bracket into the PCI card slot and fit it with the opening in the rear of the node.
  • Page 46: System Cooling

    2. Squeeze both release tabs on the top of the fan module and pull it out. 3. Replace the failed fan with an identical fan, available from Supermicro. Push the new fan into the housing, making sure the air flow direction is the same.
  • Page 47: Installing The Air Shroud

    Chapter 3: Maintenance and Component Installation Installing the Air Shroud Air shrouds and air blocks concentrate airflow to maximize fan efficiency. The air block is pre-installed and may be uninstalled by removing the two screws. Installing the Air Shroud 1. Power down the node and remove it. If an expansion card is used, install it first. 2.
  • Page 48: Power Supply

    The system features redundant power supplies. The system will continue to operate if one module fails. It should be replaced as soon as convenient. They can be changed without powering down the system. New units can be ordered directly from Supermicro or authorized distributors.
  • Page 49 Chapter 3: Maintenance and Component Installation Release Tab Figure 3-12. Replacing the Power Supply Changing the Power Supply Module 1. Unplug the AC cord from the module to be replaced. 2. On the back of the module, push the release tab, and pull the module out using the handle.
  • Page 50: Chapter 4 Motherboard Connections

    It allows the motherboard to deny access if the TPM associated with the hard drive is not installed in the system. Go to the following link for more information on the TPM: http://www.supermicro.com/manuals/other/TPM.pdf. Trusted Platform Module Header Pin Definitions...
  • Page 51 Chapter 4: Motherboard Connections M.2 Slot The motherboard has two M.2 slots (JMD1, JMD2). M.2 was formerly known as Next Generation Form Factor (NGFF) and serves to replace mini PCIe. M.2 allows for a variety of card sizes, increased functionality, and spatial efficiency. These M.2 slots support PCIe 3.0 x4/SATA 3.0 (32 Gb/s) SSD cards.
  • Page 52: Input/Output Ports

    Chapter 4: Motherboard Connections 4.2 Input/Output Ports See the figure below for the locations and descriptions of the I/O ports on the rear of the motherboard. Figure 4-1. I/O Port Locations and Definitions Rear I/O Ports Description Description USB Type C Power Switch UID Switch KVM Connector...
  • Page 53 Note: UID can also be triggered via BMC on the motherboard. For more information on BMC, please refer to the BMC User's Guide posted on our website at http://www.supermicro.com/ support/manuals/. UID Switch UID LED...
  • Page 54: Jumpers

    Chapter 4: Motherboard Connections 4.3 Jumpers How Jumpers Work To modify the operation of the motherboard, jumpers can be used to choose between optional settings. Jumpers create shorts between two pins to change the function of the connector. Pin 1 is identified with a square solder pad on the printed circuit board. Refer to the diagram below for an example of jumping pins 1 and 2.
  • Page 55 Chapter 4: Motherboard Connections Watchdog Watchdog (JWD1) is a system monitor that can reboot the system when a software application hangs. Close pins 1-2 to reset the system if an application hangs. Close pins 2-3 to generate a non-maskable interrupt (NMI) signal for the application that hangs. Refer to the table below for jumper settings.
  • Page 56 Chapter 4: Motherboard Connections Onboard TPM2.0 Enable/Disable Use JPT1 to enable or disable support for the onboard TPM 2.0 module. The default setting is Enabled. TPM Enable/Disable Jumper Settings Jumper Setting Definition Pins 1-2 Enabled (Default) Pins 2-3 Disabled VGA Enable/Disable Use jumper JPG1 to enable or disable the VGA port using the onboard graphics controller.
  • Page 57: Led Indicators

    Chapter 4: Motherboard Connections 4.4 LED Indicators OH/Power Fail/Fan Fail LED LED2 is the Overheat, Power Fail, and Fan Fail LED. See the table below for the LED status. OH/Power Fail/Fan Fail LED LED Color Definition Blinking Red Power Fail or Fan Fail Solid Red Overheat BMC Heartbeat LED...
  • Page 58: Chapter 5 Software

    USB/SATA DVD drive, or a USB flash drive, or the BMC KVM console. 2. Retrieve the proper RST/RSTe driver. Go to the Supermicro web page for your motherboard and click on "Download the Latest Drivers and Utilities", select the proper driver, and copy it to a USB flash drive.
  • Page 59 Chapter 5: Software 4. During Windows Setup, continue to the dialog where you select the drives on which to install Windows. If the disk you want to use is not listed, click on “Load driver” link at the bottom left corner. Figure 5-2.
  • Page 60: Driver Installation

    The Supermicro website contains drivers and utilities for your system at https://www. supermicro.com/wdl/driver. Some of these must be installed, such as the chipset driver. After accessing the website, go into the CDR_Images (in the parent directory of the above link) and locate the ISO file for your motherboard. Download this file to a USB flash drive or a DVD.
  • Page 61: Superdoctor ® 5

    5.3 SuperDoctor ® The Supermicro SuperDoctor 5 is a program that functions in a command-line or web-based interface for Windows and Linux operating systems. The program monitors such system health information as CPU temperature, system voltages, system power consumption, fan speed, and provides alerts via email or Simple Network Management Protocol (SNMP).
  • Page 62: Bmc

    There are several BIOS settings that are related to BMC. For general documentation and information on BMC, visit our website at: www.supermicro.com/en/solutions/management-software/bmc-resources BMC ADMIN User Password For security, each node is assigned a unique default BMC password for the ADMIN user.This can be found on a sticker on the node and a sticker on the motherboard.
  • Page 63: Chapter 6 Troubleshooting And Support

    Chapter 7: Troubleshooting and Support Chapter 6 Troubleshooting and Support 6.1 Information Resources Website A great deal of information is available on the Supermicro website, supermicro.com. Figure 7-1. Supermicro Website • Specifications for servers and other hardware are available by clicking Products. •...
  • Page 64: Bmc Interface

    Security Center for recent security notices Supermicro Phone and Addresses 6.2 BMC Interface The system supports the Baseboard Management Controller (BMC) Interface. BMC is used to provide remote access, monitoring and management. There are several BIOS settings that are related to BMC.
  • Page 65: Troubleshooting Procedures

    Chapter 7: Troubleshooting and Support 6.3 Troubleshooting Procedures Use the following procedures to troubleshoot your system. If you have followed all of the procedures below and still need assistance, refer to the Technical Support Procedures Returning Merchandise for Service section(s) in this chapter. Power down the system before changing any non hot-swap hardware components.
  • Page 66: Memory Errors

    2. Memory support: Make sure that the memory modules are supported by testing the modules using memtest86 or a similar utility. Note: Refer to the product page on our website at http://www.supermicro.com for memory and CPU support and updates. 3. HDD support: Make sure that all hard disk drives (HDDs) work properly. Replace the bad HDDs with good ones.
  • Page 67 Chapter 7: Troubleshooting and Support 5. Adequate power supply: Make sure that the power supply provides adequate power to the system. Make sure that all power connectors are connected. Please refer to our website for more information on the minimum power requirements. 6.
  • Page 68: Crash Dump Using Bmc

    In the event of a processor internal error (IERR) that crashes your system, you may want to provide information to support staff. You can download a crash dump of status information using BMC. The BMC manual is available at https://www.supermicro.com/en/solutions/ management-software/bmc-resources. Check BMC Error Log 1.
  • Page 69: Uefi Bios Recovery

    Warning: Do not upgrade the BIOS unless your system has a BIOS-related issue. Flashing the wrong BIOS can cause irreparable damage to the system. In no event shall Supermicro be liable for direct, indirect, special, incidental, or consequential damages arising from a BIOS update.
  • Page 70 USB device or a writable CD/DVD. Note 1: If you cannot locate the "Super.ROM" file in your drive disk, visit our website at www.supermicro.com to download the BIOS package. Extract the BIOS binary image into a USB flash device and rename it "Super.ROM" for the BIOS recovery use.
  • Page 71 Chapter 7: Troubleshooting and Support Note: At this point, you may decide if you want to start the BIOS recovery. If you decide to proceed with BIOS recovery, follow the procedures below. 4. When the screen as shown above displays, use the arrow keys to select the item "Proceed with flash update"...
  • Page 72 Chapter 7: Troubleshooting and Support 7. Press <Del> continuously during system boot to enter the BIOS Setup utility. From the top of the tool bar, select Boot to enter the submenu. From the submenu list, select Boot Option #1 as shown below. Then, set Boot Option #1 to [UEFI AP:UEFI: Built-in EFI Shell]. Press <F4>...
  • Page 73 Chapter 7: Troubleshooting and Support Note: Do not interrupt this process until the BIOS flashing is complete. 9. The screen above indicates that the BIOS update process is complete. When you see the screen above, unplug the AC power cable from the power supply, clear CMOS, and plug the AC power cable in the power supply again to power on the system.
  • Page 74: Cmos Clear

    Chapter 7: Troubleshooting and Support 6.6 CMOS Clear JBT1 is used to clear CMOS, which will also clear any passwords. Instead of pins, this jumper consists of contact pads to prevent accidentally clearing the contents of CMOS. To Clear CMOS 1.
  • Page 75: Where To Get Replacement Components

    6.7 Where to Get Replacement Components If you need replacement parts for your system, to ensure the highest level of professional service and technical support, purchase exclusively from our Supermicro Authorized Distributors/System Integrators/Resellers. A list can be found at: http://www.supermicro.com.
  • Page 76: Vendor Support Filing System

    For issues related to Red Hat Enterprise Linux, since it is a subscription based OS, contact your account representative. 6.9 Feedback Supermicro values your feedback as we strive to improve our customer experience in all facets of our business. Please email us at techwriterteam@supermicro.com to provide feedback on our manuals.
  • Page 77: Appendix A Standardized Warning Statements For Ac Systems

    Supermicro's Technical Support department for assistance. Only certified technicians should attempt to install or configure components. Read this appendix in its entirety before installing or configuring components in the Supermicro chassis. These warnings may also be found on our website at http://www.supermicro.com/about/...
  • Page 78 Appendix A: Warning Statements Warnung WICHTIGE SICHERHEITSHINWEISE Dieses Warnsymbol bedeutet Gefahr. Sie befinden sich in einer Situation, die zu Verletzungen führen kann. Machen Sie sich vor der Arbeit mit Geräten mit den Gefahren elektrischer Schaltungen und den üblichen Verfahren zur Vorbeugung vor Unfällen vertraut. Suchen Sie mit der am Ende jeder Warnung angegebenen Anweisungsnummer nach der jeweiligen Übersetzung in den übersetzten Sicherheitshinweisen, die zusammen mit diesem Gerät ausgeliefert wurden.
  • Page 79 Appendix A: Warning Statements . ٌ ‫ا ك ً ف حالة و ٌ يك أى تتسبب ف اصابة جسذ ة ٌ هذا الزهز ع ٌ خطز !تحذ ز‬ ‫قبل أى تعول عىل أي هعذات،يك عىل علن بالوخاطز ال ا ٌجوة عي الذوائز‬ ٍ...
  • Page 80 Appendix A: Warning Statements Warnung Vor dem Anschließen des Systems an die Stromquelle die Installationsanweisungen lesen. ¡Advertencia! Lea las instrucciones de instalación antes de conectar el sistema a la red de alimentación. Attention Avant de brancher le système sur la source d'alimentation, consulter les directives d'installation. .‫יש...
  • Page 81 Appendix A: Warning Statements Warnung Dieses Produkt ist darauf angewiesen, dass im Gebäude ein Kurzschluss- bzw. Überstromschutz installiert ist. Stellen Sie sicher, dass der Nennwert der Schutzvorrichtung nicht mehr als: 250 V, 20 A beträgt. ¡Advertencia! Este equipo utiliza el sistema de protección contra cortocircuitos (o sobrecorrientes) del edificio.
  • Page 82 Appendix A: Warning Statements 電源切断の警告 システムコンポーネントの取り付けまたは取り外しのために、 シャーシー内部にアクセスするには、 システムの電源はすべてのソースから切断され、 電源コードは電源モジュールから取り外す必要が あります。 警告 在你打开机箱并安装或移除内部器件前,必须将系统完全断电,并移除电源线。 警告 在您打開機殼安裝或移除內部元件前,必須將系統完全斷電,並移除電源線 。 Warnung Das System muss von allen Quellen der Energie und vom Netzanschlusskabel getrennt sein, das von den Spg.Versorgungsteilmodulen entfernt wird, bevor es auf den Chassisinnenraum zurückgreift, um Systemsbestandteile anzubringen oder zu entfernen.
  • Page 83 Appendix A: Warning Statements ‫يجب فصم اننظاو من جميع مصادر انطاقت وإ ز انت سهك انكهرباء من وحدة امداد‬ ‫انطاقت قبم‬ ‫انىصىل إىن امنناطق انداخهيت نههيكم نتثبيج أو إ ز انت مكىناث الجهاز‬ 경고! 시스템에 부품들을 장착하거나 제거하기 위해서는 섀시 내부에 접근하기 전에 반드시 전원 공급장치로부터...
  • Page 84 Appendix A: Warning Statements Attention Il est vivement recommandé de confier l'installation, le remplacement et la maintenance de ces équipements à des personnels qualifiés et expérimentés. !‫אזהרה‬ .‫צוות מוסמך בלבד רשאי להתקין, להחליף את הציוד או לתת שירות עבור הציוד‬ ‫واملدربيه...
  • Page 85 Appendix A: Warning Statements Warnung Diese Einheit ist zur Installation in Bereichen mit beschränktem Zutritt vorgesehen. Der Zutritt zu derartigen Bereichen ist nur mit einem Spezialwerkzeug, Schloss und Schlüssel oder einer sonstigen Sicherheitsvorkehrung möglich. ¡Advertencia! Esta unidad ha sido diseñada para instalación en áreas de acceso restringido. Sólo puede obtenerse acceso a una de estas áreas mediante la utilización de una herramienta especial, cerradura con llave u otro medio de seguridad.
  • Page 86 Appendix A: Warning Statements Battery Handling Warning! There is the danger of explosion if the battery is replaced incorrectly. Replace the battery only with the same or equivalent type recommended by the manufacturer. Dispose of used batteries according to the manufacturer's instructions 電池の取り扱い...
  • Page 87 Appendix A: Warning Statements ‫هناك خطر من انفجار يف حالة اسحبذال البطارية بطريقة غري صحيحة فعليل‬ ‫اسحبذال البطارية‬ ‫فقط بنفس النىع أو ما يعادلها مام أوصث به الرشمة املصنعة‬ ‫جخلص من البطاريات املسحعملة وفقا لحعليامت الرشمة الصانعة‬ 경고! 배터리가 올바르게 교체되지 않으면 폭발의 위험이 있습니다. 기존 배터리와 동일하거나 제 조사에서...
  • Page 88 Appendix A: Warning Statements ¡Advertencia! Puede que esta unidad tenga más de una conexión para fuentes de alimentación. Para cortar por completo el suministro de energía, deben desconectarse todas las conexiones. Attention Cette unité peut avoir plus d'une connexion d'alimentation. Pour supprimer toute tension et tout courant électrique de l'unité, toutes les connexions d'alimentation doivent être débranchées.
  • Page 89 Appendix A: Warning Statements Backplane Voltage Warning! Hazardous voltage or energy is present on the backplane when the system is operating. Use caution when servicing. バックプレーンの電圧 システムの稼働中は危険な電圧または電力が、 バックプレーン上にかかっています。 修理する際には注意く ださい。 警告 当系统正在进行时,背板上有很危险的电压或能量,进行维修时务必小心。 警告 當系統正在進行時,背板上有危險的電壓或能量,進行維修時務必小心。 Warnung Wenn das System in Betrieb ist, treten auf der Rückwandplatine gefährliche Spannungen oder Energien auf.
  • Page 90 Appendix A: Warning Statements ‫هناك خطز مه التيار الكهزبايئ أوالطاقة املىجىدة عىل اللىحة‬ ‫عندما يكىن النظام يعمل كه حذ ر ا عند خدمة هذا الجهاس‬ 경고! 시스템이 동작 중일 때 후면판 (Backplane)에는 위험한 전압이나 에너지가 발생 합니다. 서비스 작업 시 주의하십시오. Waarschuwing Een gevaarlijke spanning of energie is aanwezig op de backplane wanneer het systeem in gebruik is.
  • Page 91 Appendix A: Warning Statements ‫תיאום חוקי החשמל הארצי‬ !‫אזהרה‬ .‫התקנת הציוד חייבת להיות תואמת לחוקי החשמל המקומיים והארציים‬ ‫تركيب املعدات الكهربائية يجب أن ميتثل للقىاويه املحلية والىطىية املتعلقة‬ ‫بالكهرباء‬ 경고! 현 지역 및 국가의 전기 규정에 따라 장비를 설치해야 합니다. Waarschuwing Bij installatie van de apparatuur moet worden voldaan aan de lokale en nationale elektriciteitsvoorschriften.
  • Page 92 Appendix A: Warning Statements Attention La mise au rebut ou le recyclage de ce produit sont généralement soumis à des lois et/ou directives de respect de l'environnement. Renseignez-vous auprès de l'organisme compétent. ‫סילוק המוצר‬ !‫אזהרה‬ .‫סילוק סופי של מוצר זה חייב להיות בהתאם להנחיות וחוקי המדינה‬ ‫التخلص...
  • Page 93 Appendix A: Warning Statements Warnung Gefährlich Bewegende Teile. Von den bewegenden Lüfterblätter fern halten. Die Lüfter drehen sich u. U. noch, wenn die Lüfterbaugruppe aus dem Chassis genommen wird. Halten Sie Finger, Schraubendreher und andere Gegenstände von den Öffnungen des Lüftergehäuses entfernt.
  • Page 94 Verbindungskabeln, Stromkabeln und/oder Adapater, die Ihre örtlichen Sicherheitsstandards einhalten. Der Gebrauch von anderen Kabeln und Adapter können Fehlfunktionen oder Feuer verursachen. Die Richtlinien untersagen das Nutzen von UL oder CAS zertifizierten Kabeln (mit UL/CSA gekennzeichnet), an Geräten oder Produkten die nicht mit Supermicro gekennzeichnet sind.
  • Page 95 ‫.قيرح وأ لطع يف ببستي دق ىرخأ تالوحمو تالباك يأ مادختسا .ميلسلا سباقلاو لصوملا مجح‬ ‫ لبق نم ةدمتعملا تالباكلا مادختسا تادعملاو ةيئابرهكلا ةزهجألل ةمالسلا نوناق رظحي‬UL ‫ وأ‬CSA ‫( ةمالع لمحت يتلاو‬UL/CSA) ‫ لبق نم ةددحملاو ةينعملا تاجتنملا ريغ ىرخأ تادعم يأ عم‬Supermicro.
  • Page 96 사항을 준수하여 제공되거나 지정된 연결 혹은 구매 케이블, 전원 케이블 및 AC 어댑터를 사용하십시오. 다른 케이블이나 어댑터를 사용하면 오작동이나 화재가 발생할 수 있습니다. 전기 용품 안전법은 UL 또는 CSA 인증 케이블 (코드에 UL / CSA가 표시된 케이블)을 Supermicro 가 지정한 제품 이외의 전기 장치에 사용하는 것을 금지합니다. Stroomkabel en AC-Adapter...
  • Page 97: Appendix B System Specifications

    Appendix B: System Specifications Appendix B System Specifications Processors (per node) Supports an Intel Xeon E-2300 Family processor and Pentium processor with up to 95W in an LGA1200 socket Note: Refer to the motherboard specifications pages on our website for updates to supported processors. Chipset (per node) Intel C256 BIOS...
  • Page 98 Appendix B: System Specifications Regulatory Compliance FCC, ICES, CE, VCCI, RCM, UKCA, NRTL, CB Applied Directives, Standards EMC/EMI: 2014/30/EU (EMC Directive) Electromagnetic Compatibility Regulations 2016 FCC Part 15 ICE-003 VCCI-CISPR 32 AS/NZS CISPR 32 BS/EN55032 BS/EN55035 CISPR 24/CISPR 35 BS/EN 61000-3-2 BS/EN 61000-3-3 BS/EN 61000-4-2 BS/EN 61000-4-3...