"With occupied
sensors" selected
X
-
Timeout (sec): Used to set the time, between 10 sec and infinity, by which the Override
function must end.
Override mode: Used to configure the type of Override (pulsed or maintained action).
With OverOut: Used to activate an Override active Signaling output (active when high).
With Request: Used to activate a Signaling output (active when high) indicating that the
Override function can be activated.
Manual Reset:
Should the INPUT be active (TRUE), the reset enables the output of the function block.
Should the INPUT be not active (FALSE), the output of the function block follows the
OVERRIDE request.
There are two types of reset: Manual and Monitored. When Manual is selected the system
only verifies the signal's transition from 0 to 1. If Monitored is selected the double transition
from 0 to 1 and then back to 0 is verified.
8540780 • 25/01/2023 • Rev.43
Light
Occupied
curtain
sensor
occupied
X
-
-
X
X
-
X
X
t = 250 ms
Override
Input
request
0
1
0
1
0
1
0
1
5s > t1 > 250 ms
t2 = 250 ms
Override
output
1
1
1
1