Nova430e Outdoor 4x250mW Two-Carrier TDD eNodeB Installation Guide
3.7.9 Verify eNB Operational Status
When the eNB is finished rebooting, check the eNB status using the eNB GUI and the OMC. Once the eNB
is mounted at its intended destination and powered on, recheck the status settings.
eNB GUI: Go to Basic Setting > Basic Info and check the Cell Status field. It should show Active.
•
Also, check that GPS Sync Status is reported as Synchronized (Figure 3-28).
•
OMC: Go to Monitor > eNB to see if the Cell Status shows Active and the Sync Status shows GPS
Synchronized (Figure 3-29).
NOTE: To manage which columns of information are displayed on the Monitor > eNB page, select
the Settings icon
columns display. Select a category, then drag and drop it in the preferred order (Figure 3-30).
Figure 3-28: Cell Status (eNB GUI)
Figure 3-29: Cell Status (OMC)
NOTE: This image is captured with customized filters for Cell Status and Sync Status applied.
in the upper left of the window. You can customize the order in which the
40