Nova430e Outdoor 4x250mW Two-Carrier TDD eNodeB Installation Guide
Field Name
Netmask
Gateway
Prefix
IPv6 Gateway
IP Address
VLAN ID
DNS Config Pane
Index
DNS Address
MTU Config Pane
MTU
Allow Management Access Over WAN Pane
Allow Management Access
Over WAN
LAN Config Tab
LAN Config Pane
IP Address
Subnet Mask
3.7.4.2 LGW
The Local Gateway (LGW) must be configured when the Baicells CloudCore Evolved Packet Core (EPC) is
used. The Baicells eNodeB (eNB) splits the data and control planes, so there are two IP addresses per
Customer Premise Equipment (CPE). The data plane is sent out to the LGW, while the control plane is
routed through an IPSec tunnel to the Baicells CloudCore EPC.
Refer to Figure 3-21 and Table 3-2 to configure LGW. You must reboot the eNB when you make changes to
these settings.
Description
The IP address' subnet mask address. This parameter displays when IP Access
Mode is set to Static IP.
The default gateway's IP address. This parameter displays when IP Access
Mode is set to Static IP.
The IPv6 address' prefix for the WAN interface. This parameter displays when
IP Access Mode is set to IPv6 Static IP. Range is 0–128.
The IPv6 address' gateway for the WAN interface. This parameter displays
when IP Access Mode is set to IPv6 Static IP.
The WAN interface's IP address. This parameter displays when IP Access Mode
is set to Static IP or IPv6 Static IP.
Used to configure more IP addresses for the WAN interface through the VLAN
when there is a need to transmit multi-types of data through a separate
channel. Range is 1–4094.
The DNS index number, which is generated automatically.
The IP address assigned to the DNS. The maximum number of configurations is
two.
Used to specify the size of the largest network layer protocol data unit that
can be communicated in a single network transaction. Specifying the correct
MTU for the network can help to improve data transmission efficiency. Range
is 700 to 1600 bytes. The default value is 1500 bytes.
Used to enable/disable the Local Maintenance Terminal connection through
the WAN port (ON or OFF) for management purposes. If set to ON, the
administrator can maintain the eNB through the WAN interface.
The LAN interface IP address. The default value is 192.168.150.1.
Used to define the subnet mask address for the LAN interface. The default
value is 255.255.255.0.