Connect Cables; Cable Laying Requirements; Figure 3-11: Attach Enb To Bracket - Baicells Nova430e Installation Manual

Outdoor 4x250mw two-carrier tdd enodeb
Hide thumbs Also See for Nova430e:
Table of Contents

Advertisement

Nova430e Outdoor 4x250mW Two-Carrier TDD eNodeB Installation Guide
5. Align the two pins on the eNB bracket to the pin holes on the wall bracket (refer to Figure 3-7),
and lower the pins vertically into the pin holes, ensuring the hooks on the eNB are firmly attached
in the slots on the wall bracket. Tighten the screw on the top of the bracket using a Phillips-head
screwdriver to complete the installation (Figure 3-11).

Figure 3-11: Attach eNB to Bracket

3.4 Connect Cables

3.4.1 Cable Laying Requirements

General requirements:
Bending radius of antenna feeder cable:
 7/8 in > 9.84 in (22.2 mm > 250 mm)
 4/5 in > 14.96 in (20.3 mm > 380 mm)
Bending radius of jumper cable:
 1/4 in > 1.38 in (6.3 mm > 35 mm)
 super soft 1/2 in > 1.97 in (13 mm > 50 mm)
 ordinary 1/2 in > 5 in (13 mm > 127 mm)
Bending radius of power cable and grounding cable: > triple the diameter of the cable.
Bind the cables according to the type of cable; intertwining and crossing are forbidden.
An identification label should be attached after the cable is laid.
Grounding cable requirements:
The grounding cable must connect to the grounding point.
The grounding cable must be separated from the signal cables, and of enough distance to avoid
signal interference.