5. From top to bottom, lower the eNB bracket's hook into the wall bracket, ensuring the hook on the
eNB is firmly attached in the slot on the wall bracket. Tighten the screw on the top of the wall
bracket using a Phillips-head screwdriver to complete the installation (Figure 3-9).

Figure 3-9: Completed Installation

3.3 Connect Cables

WARNING:
Ensure the antenna is connected before powering up the eNB. The wireless signal
transmission power can cause bodily injury and damage to the eNB and Radio Frequency (RF)
power amplifier devices.

3.3.1 Cable Laying Requirements

General requirements:
Bending radius of antenna feeder cable:
7/8 in > 9.84 in (22.2 mm > 250 mm)
4/5 in > 14.96 in (20.3 mm > 380 mm)
Bending radius of jumper cable:
1/4 in > 1.38 in (6.3 mm > 35 mm)
super soft 1/2 in > 1.97 in (13 mm > 50 mm)
ordinary 1/2 in > 5 in (13 mm > 127 mm)
Bending radius of the power cable and grounding cable: > triple the diameter of the cable.
Bind the cables according to the cable type; intertwining and crossing are forbidden.
An identification label should be attached after the cable has been laid.
Grounding cable laying requirements:
The grounding cable must connect to the grounding point.
The grounding cable must be separated from the signal cables with enough distance to avoid signal
interference.