YASKAWA CIMR-F7Z44P0 User Manual page 128

E7 drive
Table of Contents

Advertisement

o1-02 Power-On Monitor
Setting
1
Frequency Reference (factory default)
2
Output Frequency
3
Output Current
4
User Monitor (set by o1-01)
When the Drive is powered up, three monitors are displayed on the digital operator. The first and largest monitor is the
"Power-On" monitor. The factory default "Power-On monitor" is Speed Command (U1-01). Below the Speed Command
monitor are the next two sequential monitors, Output Frequency (U1-02) and Output Current (U1-03). Pressing the
INCREASE key once scrolls the monitors to show the User Monitor as selected by o1-01. The factory default for o1-01 is the
Output Voltage monitor (U1-06).
The active monitor displayed when the Drive is powered on can be changed to either be U1-01 (Speed Command), U1-02
(Output Frequency), U1-03 (Output Current), or the User Monitor. Whichever monitor is selected as the Power-On top moni-
tor, the two monitors displayed below it are the next two sequential monitors. See example below.
Active Monitor
For example, if the Drive needs to display the Elapsed Timer as the Power-On monitor, then o1-01 must be set to "13" and
o1-02 must be set to "4". The next time Drive power is cycled, the digital operator displays U1-13 (Elapsed Time), U1-14
(Flash ID), and U1-15 (Term AI Level).
Active Monitor
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Description
-DRIVE-
Frequency Ref
U1-01=
60.00Hz
- - - - - - - - - - - - - - - - - - - - - - - - - - - - -
U1-02=
60.00Hz
U1-03=
10.05A
-DRIVE-
Elapsed Time
U1-13=
2
H
- - - - - - - - - - - - - - - - - - - - - - - - - - - - -
U1-14= 03010
15
U1-16=
51.2%
Programming 5 - 53
Rdy
Active Monitor Title
Next two
Output Frequency
sequential
Output Current
monitors
Rdy
Active Monitor Title
Next two
Flash ID
sequential
Term AI Level
monitors