Fujitsu PRIMERGY CX2550 M6 Upgrade And Maintenance Manual page 226

Table of Contents

Advertisement

System board and components
Figure 157: Installing the TPM
▶ Connect the TPM to the system board (1).
▶ Fasten the TPM with the special screw for the TPM using the TPM bit insert
or TPM module fixing tool (Japan) (2).
CAUTION
Do not fasten the screw too firmly.
Stop it by extent where the head of the screw lightly touches the
TPM. Torque: 0.6 Nm (not used in Japan).
Concluding steps
▶ Install the riser modules, see
▶ Reconnect all cables to the system board. For a complete cabling overview,
see
"Cabling" on page
"Resuming BitLocker functionality" on page
▶ Enable the TPM in the system board BIOS, see
system board
BIOS".
Enabling the TPM in the system board BIOS
▶ Switch on or restart your server.
▶ As soon as the startup screen appears, press the [F2] function key to enter
the BIOS setup menu.
▶ Select the Configuration menu.
▶ Select the Security Configuration submenu.
226
"Installing a riser module" on page
265.
Upgrade and Maintenance Manual
81.
"Enabling the TPM in the
51.