TECHNICAL SPECIFICATIONS
LED AND BEEPER INDICATIONS
Buttons and LED Status
The top of the product has a button and three indicator LEDs:
Table 20LED Indications
Indicators
The reader's beeper sounds and its LED illuminates to indicate various functions or
errors on the reader. An optional "Green Spot" also performs useful functions. The fol-
lowing tables list these indications. One exception to the behaviors listed in the table is
that the reader's functions are programmable, and so may or may not be turned on. For
example, certain indications such as the power-up beep can be disabled using program-
ming bar code labels.
Power-up
Good Read
ROM Failure
Limited Scanning Label
Read
Imager Disabled
252
GRYPHON™ GFS4500
POWER LED
(green)
STATUS LED
(Multicolor)
INDICATION
Upper LED flashes/
blinks on power-up,
however, this may be too
rapid to view. With a USB
interface, the LED blinks
until enumeration with
the host is completed.
Upper green LED comes
on for programmed time
(default).
LED behavior for this
indication is configurable
using Aladdin utility.
200ms on / 200ms off
N/A
The LED blinks continu-
ously 100ms on / 900ms
off
ON = Power ON
Blinking = USB enumeration (USB version only) or
FW Upgrade
OFF = Power OFF or Limited Scanning Mode or
Standby (USB version only)
Green = Good Read, USB enumeration (USB version
only) or FW Upgrade
Blue = External trigger, or button pressed or phase
active or Image Capture mode.
RED = Used to indicate Wrong Code or No Read,
depending on the configuration (see Product Refer-
ence Guide).
LED
Imager beeps four times at highest
frequency and volume upon power-
up.
One beep at current frequency, vol-
ume, mono/bi-tonal setting upon a
successful label scan. It is also pos-
sible to upload custom jingles with
Aladdin.
Imager sounds one error beep at
highest volume for 200 mS.
Imager 'chirps' six times at the
highest frequency and current vol-
ume.
N/A
BEEPER