CODE 39
The following options apply to the Code 39 symbology.
Code 39 Enable/Disable
When disabled, the reader will not read Code 39 bar codes.
$CC3EN00
Code 39 = Enable
Code 39 Check Character Calculation
Enable this option to enable/disable calculation and verification of an optional Code 39
check character. When disabled, any check character in the label is treated as a data
character.
$CC3CC00
Code 39 Check Character Calculation = Calculate Std Check
$CC3CC02
Code 39 Check Character Calculation = Enable Italian Post
CODE 39
Check
ENTER/EXIT PROGRAMMING MODE
Code 39 = Disable
$CC3EN01
Code 39 Check Character Calculation = Don't Calcu-
$CC3CC01
Code 39 Check Character Calculation = Calculate Mod 7
Check
$CC3CC04
late
PRODUCT REFERENCE GUIDE