Operating Manual
MHM-97442
Figure 7-9: Function generator - example eddy current sensor signal
A. Function generator
B. 9-pole Sub-D terminal block monitor A, B, and C (analog signals)
C. AMS 6300 SIS
D. Sensor supply
E. Signal input
F. Function generator signal
Note
To avoid disturbances of the monitor, ensure that the output of the function generator is
floating — the signal ground must be isolated from ground.
MHM-97442, Rev. 2.06
Functions and applications
February 2023
147