Installation And Commissioning; Mounting Of The System - Emerson Machinery Health AMS 6300 SIS Operating Manual

Overspeed protection system
Table of Contents

Advertisement

Operating Manual
MHM-97442
4

Installation and commissioning

This chapter describes mounting, installation, connection, and commissioning of the
AMS 6300 SIS Overspeed Protection System and the requirements on the trigger wheel
together with the required arrangement of the sensors at the trigger wheel.
4.1

Mounting of the system

The steps below describe the mounting of the AMS 6300 SIS system.
system assembly.
Figure 4-1: Assembly drawing
Prerequisites
You will need the following equipment to assemble the rack and mount it in a cabinet:
Philips screwdriver size PH1 for mounting the backplane
Suitable Phillips screwdriver for mounting the System Rack with the cage nuts into the
cabinet
Suitable flathead screwdriver (for example 3.5 x 0.6 x 100 mm) for the terminal blocks
Procedure
1. If the A6371/xx backplane is not already screwed on the rear of the A6352 19"
2. Mount the backplane as shown in
3. Check the position of the guide rails for the monitors. The rails have to be on
MHM-97442, Rev. 2.06
frame, mount the backplane with the enclosed mounting kit, consisting of two
plastic rails and 10 assembly screws.
position 1, 15, and 29 as shown in
Installation and commissioning
Figure
4-1.
Figure
4-2.
February 2023
Figure 4-1
shows the
25