Emerson Machinery Health AMS 6300 SIS Operating Manual page 144

Overspeed protection system
Table of Contents

Advertisement

Functions and applications
February 2023
Test values
The test values serve the check of monitor functions, for example, during installation and
commissioning when measuring signals from the machine are not yet available.
After the activation, the entered constant test value is checked instead of the measuring
value when the measuring value is smaller than the test value. Only one test value can be
activated at any one time. Since the test value is not supervised as long as it is smaller than
the current measuring value, the overspeed protection remains active even while this test
is carried out.
144
Figure 7-8: Report of a successful proof test
Operating Manual
MHM-97442
MHM-97442, Rev. 2.06