NIC1 LED
The NIC1 (Network Interface Con-
troller) LED connection is located
on pins 11 and 12 of JF2. Attach
the NIC1 LED cable to display net-
work activity.
Refer to the table
on the right for pin definitions.
NIC2 LED
The NIC2 (Network Interface Con-
troller) LED connection is located
on pins 9 and 10 of JF2.
the NIC2 LED cable to display net-
work activity.
Refer to the table
on the right for pin definitions.
Overheat LED (OH)
Connect an LED to the OH connec-
tion on pins 7 and 8 of JF2 to pro-
vide advanced warning of chassis
overheating. Refer to the table on
the right for pin definitions.
Power Fail LED
The Power Fail LED connection is
located on pins 5 and 6 of JF2.
Refer to the table on the right for
pin definitions.
This only applies
to redundant power supplies and
so does not apply to the 6013P-8+.
Reset Button
The Reset Button connection is lo-
cated on pins 3 and 4 of JF2. At-
tach it to the hardware reset
switch on the computer case.
Refer to the table on the right for
pin definitions.
Chapter 5: Advanced Serverboard Setup
Attach
5-13
NIC1 L ED Pin
Definitions
(JF 2)
Pin
Number
Definition
11
Vcc
12
GND
NIC2 L ED Pin
Definitions
(JF 2)
Pin
Number
Definition
9
Vcc
10
GND
Overheat (OH) LED
Pin Definitions
(JF 2)
Pin
Number
Definition
7
Vcc
8
GND
Power Fail LED Pin
Definitions
(JF 2)
Pin
Number
Definition
5
Vcc
6
GND
Reset Pin
Definitions
(JF 2)
Pin
Number
Definition
3
Reset
4
Ground