The Dynamic Brake At The Load Inertia Moment; Encoder Cable Flexing Life - Mitsubishi Electric MR-J2S B Series Instruction Manual

Servo amplifier
Table of Contents

Advertisement

11. CHARACTERISTICS

11.3.2 The dynamic brake at the load inertia moment

Use the dynamic brake under the load inertia moment ratio indicated in the following table. If the load
inertia moment is higher than this value, the built-in dynamic brake may burn. If there is a possibility
that the load inertia moment may exceed the value, contact Mitsubishi.
Note. Assumes that the external dynamic brake is used.

11.4 Encoder cable flexing life

The flexing life of the cables is shown below. This graph calculated values. Since they are not guaranteed
values, provide a little allowance for these values.
Servo amplifier
MR-J2S-10B to MR-J2S-200B
MR-J2S-10B1 to MR-J2S-40B1
MR-J2S-350B
MR-J2S-500B
MR-J2S-700B
(Note)MR-J2S-11KB to MR-J2S-22KB
1 10
8
5 10
7
1 10
7
5 10
6
1 10
6
5 10
5
1 10
5
5 10
4
1 10
4
5 10
3
1 10
3
4
7
10
Load inertia moment ratio [times]
a
b
20
40
70 100
Flexing radius [mm]
11 - 7
30
16
15
(Note) 30
a : Long flexing-life encoder cable
MR-JCCBL M-H
MR-JHSCBL M-H
MR-ENCBL M-H
b : Standard encoder cable
MR-JCCBL M-L
MR-JHSCBL M-L
200

Advertisement

Table of Contents
loading

Table of Contents