12. OPTIONS AND AUXILIARY EQUIPMENT
(3) Outside dimensions of the power regeneration converters
Rating plate
Front cover
Power
regeneration
A
converter
270
FR-RC-15K
(10.6)
340
FR-RC-30K
(13.4)
480
FR-RC-55K
(18.9)
(4) Mounting hole machining dimensions
When the power regeneration converter is fitted to a totally enclosed type box, mount the heat
generating area of the converter outside the box to provide heat generation measures. At this time, the
mounting hole having the following dimensions is machined in the box.
2- D hole
D
AA
A
AA
B
BA
200
450
432
(7.87)
(17.7)
(17.0)
270
600
582
(10.6)
(23.6)
(22.9)
410
700
670
(16.1)
(27.6)
(26.4)
(2- D hole)
(AA)
(Mounting hole)
a
Mounting foot (removable)
Mounting foot
movable
Display
panel
window
C
Heat generation area outside mounting dimension
C
D
E
195
10
10
(7.68)
(0.39)
(0.39)
195
10
10
(7.68)
(0.39)
(0.39)
250
12
15
(9.84)
(0.47)
(0.59)
Model
FR-RC-15K
FR-RC-30K
FR-RC-55K
12 - 19
[Unit : mm(in)]
Cooling fan
K
F
EE
K
F
8
3.2
87
(0.32)
(0.13)
(3.43)
8
3.2
90
(0.32)
(0.13)
(3.54)
15
3.2
135
(0.59)
(0.13)
(5.32)
A
B
D
260
412
10
(10.2)
(16.2)
(0.39)
330
562
10
(13.0)
(22.1)
(0.39)
470
642
12
(18.5)
(25.3)
(0.47)
Approx.
mass [kg(Ib)]
19
(41.9)
31
(68.3)
55
(121)
[Unit : mm(in)]
AA
BA
200
432
(7.87)
(17.0)
270
582
(10.6)
(22.9)
410
670
(16.1)
(26.4)