Auto Tuning Mode Operation - Mitsubishi Electric MR-J2S B Series Instruction Manual

Servo amplifier
Table of Contents

Advertisement

6. GENERAL GAIN ADJUSTMENT

6.2.2 Auto tuning mode operation

The block diagram of real-time auto tuning is shown below.
Command
Parameter No.8
1
Auto tuning selection
When a servo motor is accelerated/decelerated, the load inertia moment ratio estimation section always
estimates the load inertia moment ratio from the current and speed of the servo motor. The results of
estimation are written to parameter No. 12 (the ratio of load inertia moment to servo motor). These
results can be confirmed on the status display screen of the MR Configurator (servo configuration
software) section.
If the value of the load inertia moment ratio is already known or if estimation cannot be made properly,
chose the "auto tuning mode 2" (parameter No. 8: 0003) to stop the estimation of the load inertia moment
ratio (Switch in above diagram turned off), and set the load inertia moment ratio (parameter No. 12)
manually.
From the preset load inertia moment ratio (parameter No. 12) value and response level (parameter No. 9),
the optimum control gains are automatically set on the basis of the internal gain tale.
The auto tuning results are saved in the EEP-ROM of the servo amplifier every 6 minutes since power-on.
At power-on, auto tuning is performed with the value of each control gain saved in the EEP-ROM being
used as an initial value.
Automatic setting
Control gains
PG1,VG1
PG2,VG2,VIC
Set 0 or 1 to turn on.
Gain
table
Parameter No.9
5
Response level setting
POINT
If sudden disturbance torque is imposed during operation, the estimation of
the inertia moment ratio may malfunction temporarily. In such a case,
choose the "auto tuning mode 2" (parameter No. 8: 0003) and set the correct
load inertia moment ratio in parameter No. 12.
When any of the auto tuning mode 1, auto tuning mode 2 and manual mode
1 settings is changed to the manual mode 2 setting, the current control
gains and load inertia moment ratio estimation value are saved in the EEP-
ROM.
Current feedback
Real-time auto
tuning section
Load inertia
moment ratio
Switch
estimation section
Parameter No.12
Load inertia moment
ratio estimation value
6 - 5
Load inertia
moment
Current
Servo
control
motor
Position/speed
feedback
Speed feedback
Encoder