Remedies For Alarms - Mitsubishi Electric MR-J2S B Series Instruction Manual

Servo amplifier
Table of Contents

Advertisement

9. TROUBLESHOOTING

9.2 Remedies for alarms

CAUTION
When an alarm occurs, the dynamic brake is operated to stop the servo motor. At this time, the display
indicates the alarm No.
The servo motor comes to a stop. Remove the cause of the alarm in accordance with this section. The MR
Configurator (servo configuration software) may be used to refer to the cause.
Display
Name
10
Undervoltage
12
Memory error 1 RAM, memory fault
13
Clock error
When any alarm has occurred, eliminate its cause, ensure safety, then reset the
alarm, and restart operation. Otherwise, injury may occur.
If an absolute position erase alarm (25) occurred, always make home position
setting again. Otherwise, misoperation may occur.
As soon as an alarm occurs, mark Servo-off and power off the main circuit and
control circuit.
POINT
When any of the following alarms has occurred, always remove its cause
and allow about 30 minutes for cooling before resuming operation. If
operation is resumed by switching control circuit power off, then on to reset
the alarm, the servo amplifier and servo motor may become faulty. To
protect the main circuit elements, any of these servo alarms cannot be
deactivated from the servo system controller until the specified time elapses
after its occurrence. Judging the load changing condition until the alarm
occurs, the servo amplifier calculates this specified time automatically.
Regenerative error (30)
Overload 1 (50)
Overload 2 (51)
The alarm can be deactivated by switching power off, then on or by the
error reset command CPU reset from the servo system controller. For
details, refer to section 9.1.
Definition
Power supply
1. Power supply voltage is low.
voltage dropped.
2. There was an instantaneous
MR-J2S- B:
control circuit power failure of
160VAC or less
60ms or longer.
MR-J2S- B1:
3. Shortage of power supply capacity
83VAC or less
caused the power supply voltage to
drop at start, etc.
4. Main voltage has dropped to the
following voltage or less.
MR-J2S- B: 200VDC
MR-J2S- B1: 158VDC
5. Faulty parts in the servo amplifier
Alarm (10) occurs if power is
switched on after CN1A, CN1B
and CN3 connectors are
disconnected.
Faulty parts in the servo amplifier
Printed board fault
Alarm (any of 12 and 13)
occurs if power is switched on
after disconnection of all cables
but the control circuit power
supply cables.
Cause
Checking method
Checking method
9 - 2
Action
Check the power supply.
Change the servo amplifier.
Change the servo amplifier.

Advertisement

Table of Contents
loading

Table of Contents