3.6.3
5V Digital I/O Connection
Remarks:
1. The inputs are compatible with TTL(5V), LVTTL(3.3V), CMOS and open collector outputs
2.
The outputs are compatible with TTL (5V) and CMOS (5V) inputs
3. The output loads can be individually and independently connected to +5V or to GND.
4.
The length of the cables must be up to 30m, reducing the exposure to voltage surges in industrial environment.
Technosoft 2022
Figure 3.5. 5V Digital I/O connection
18
iPOS360x MX-CAN Technical Reference