INSTALLATION IN AN ELEVATED CABINET
Cabin must match the dimensions provided in figure 4.
The clearances with the dimensions indicated in the figure must be provided at the rear part of cabin, upper
and lower sections so that necessary ventilation can be achieved.
INSTALLATION REQUIREMENTS
Product dimensions are provided in the figure 3.
Furniture surfaces for mounting and mounting materials to be used must have a minimum temperature
resistance of 100 °C.
Mounting cabin must be secured and its floor must be plane for product not to tilt over. Cabin floor must
have a minimum strength that would handle a load of 60 kg.
PLACING AND SECURING THE OVEN
Place the oven into the cabin with two or more people. Ensure that oven's frame and front edge of the
furniture match uniformly.
Supply cord mustn't be under the oven, squeeze in between oven and furniture or bend.
Fix the oven to the furniture by using the screws provided with the product. Screws must be mounted as
shown in figure 5 by passing them through plastics attached to frame of the product. Screws mustn't be
overtightened. Otherwise, screw sockets might be worn.
Check that oven doesn't move after mounting. If oven isn't mounted in accordance with instructions, there
is a risk of tilt over during operation.
ELECTRICAL CONNECTION
Mounting place of the product must have appropriate electrical installation. Network voltage must be
compatible with the values provided on type label of product.
Product connection must be made in accordance with local and national electrical requirements.
Before starting the mounting disconnect network power. Do not connect the product to network until its
mounting is completed.
47