Error
LED
In-
Code
dictor
Error 01
Error 05
Error 06
Error 08
Yellow
LEDs on
or
Yellow LEDs
flash once per
Error 09
second.
Error 10
Error 11
Error 12
Error 13
Error 14
LED
Description
Display
Hardware error Wait for automatic recovery. If the
Hardware error
Circuit breaker
open
LMU
disconnect
(Second-
ary)
SN missing
LMU
Disconnect
(Primary)
Software
version in-
consistent
Multiple Primary
Batteries (there
should be only
one Primary)
MOS
over temperature
Insulation fault
Troubleshooting
problem is not be solved yet, please
call the service centre.
Switch on circuit breaker after power-
ing off the battery.
Reconnect the BMS communication ca-
ble.
Call for service.
Reconnect the BMS communication ca-
ble.
Call for service.
Restart all batteries.
Power off the battery and power on
the battery after 30 minutes.
Restart battery and in case the prob-
lem is not resolved, call for service.