76
100050
Grid_overcurrent
100051
Grid_current_track_fault
100052
Backup_ovp
100053
Dc_bus_unbalancevolt
100054
Dc_bus_undervolt
100055
Dc_bus_unbalancevolt2
100056
IGBT_over_current
100057
Grid_disturbance2
100058
AFCI_check_protect
Grid_current_sampling_
100059
abnormal
100060
Dsp_selfcheck
Grid_short_time_over_
100061
current
100062
Bat_overvolt_hardware_fault
Maintenance and Troubleshooting
3. Restart inverter and check whether the
fault is existing.
Restart inverter and check whether the fault
is existing.
1. Check whether backup cable connection is
normal.
2. Restart inverter and confirm whether the
fault is existing.
Switch off the PV switch & all AC and BAT
circuit breakers in the energy storage
system, then restart it as chapter 8.1
Powering on the Product and check whether
the fault is existing.
Switch off the PV switch & all AC and BAT
circuit breakers in the energy storage
system, then restart it as chapter 8.1
Powering on the Product and check whether
the fault is existing.
1. Confirm whether grid is distorted severely.
2. Check whether PV cable connection is
reliable.
1. Check whether PV cable connection is
reliable.
2. Check whether PV cable is damaged.
1. Confirm whether grid is distorted severely.
2. Check whether PV cable connection is
reliable.
Restart inverter and check whether the fault
is existing.
1. Confirm whether grid is distorted severely.
2. Check whether PV cable connection is
reliable.
1. Check whether battery breaker has
tripped off.
2. Check whether battery operation is
normal.