72

9.5.2. Check the PV Generation and Discharging Function of the Product

This chapter is only suitable for SMILE-S5.
Step1:
Please switch off the PV switch on the energy storage inverter and the AC
breaker on the PV inverter if there is any. Switch on some larger loads to see the
battery discharging status.
Step 2:
Please switch on the PV switch on the energy storage inverter and the AC
breaker on the PV inverter if there is any. Check the running status of the system.
COMMISSIONING
The relative value should be like this:
Load = GRID
+
Battery
The relative value should be like this:
±
±
Load = PV
GRID
Battery
±:
charging: - ; discharging:
PV arrow
should be as the picture shows.
±:
>>absorbing from grid: +;
<<
feed-in to grid:-
If not correct, please check the CT or meter installed
direction on PV side
+