Alpha ESS SMILE5 Installation, Operation & Maintenance Manual page 26

Energy storage system
Table of Contents

Advertisement

47
> > >
Setting
< < <
> Function
Safety
Step 2: Click Function to enter function
setting.
> > >
Solar
< < <
> On Grid Cap.
000000W
Step 4: Set on-grid capacity, storage
capacity and number of PV strings (MPPT
number).
On-grid capacity: Existing PV capacity
Storage capacity: PV capacity on SMILE5
> > >
Battery
< < < <
> SOC Calibration
No
Step 6: Check SOC Calibration
function set No.
> > > > >
Grid
< < < < <
> FeedIN Control
Power Limit
Power Factor
Step 8: Click the Grid Function to set
up relevant parameters about the grid
EMS INTRODUCTION AND SET UP
> > >
Function
< < <
> Solar
Battery
Grid
Step 3: Click Solar to set the Solar relevant
information.
> > >
Battery
< < < <
> Bat Model
Smile5-BAT
Step 5: Click the Battery Function and
check battery type SMILE5-BAT.
> > >
Battery
< < < <
> Battery Ready
No
Step 7: Check the Battery Ready
function set No. If you only use the
inverter without battery, please set it
Yes.
Max. Feed in rate
> User Value:
50%
Step 9: Set the Max. Feed in rate value.
For example, the storage capacity is
6.6kW, the on grid capacity is 3kW,
feed-in power is limited within 5kW,
then the max. feed in rate = 5 / (6.6+3)
≈ 52%
EMS INTRODUCTION AND SET UP
> >
System Mode
< <
> DC
AC
Hybrid
Step 10: Click Function-System Mode to
set system mode: DC, AC, Hybrid.
> > >
Work Mode
< <
> Force Charge
Enable
Step 12: If you want to use force
charge, set Enable here.
> > >
Work Mode
< <
> UPS Resernve SOC
11%
Step 14: Set the UPS Reserve SOC, it
means how much battery energy left for
UPS function.
>
> >
CT Meter
>
Enable
OFF
Ratio
1
Step 16: If you use CT meter, please set
CT meter enable and the relevant ratio
> > >
Work Mode
< <
> Force Charge
Enable
Step 11: Click the mode then set
up work mode.(self-use or force
time charge)
> > >
Work Mode
< <
>
Charge
Start Time 1
01 : 00
Step 13: Set the charge and discharge
time.
> > > >
Safety
< < < <
> Country
AS4777
Step 15: Click Safety in the setting
menu. Set safety standard.
AS4777.2 for Australia, VDE4105/11.18
f o r G e r m a n y , C E I 0 - 2 1 f o r I t a l y ,
G98/G99 for Britain, NRS097-2-1 for
South Africa, RD1699 for Spain. For
other details please find in Section 9.2.
For Volt-var/watt function in South
Australia please choose AS4777-SA.
>
>
UPS System
>
Mute
YES
Frequency:
50Hz
Step 17: If you use UPS function, please
set the mute as YES in UPS System
interface and the relevant Frequency.