L.B. White Journeyman Owner's Manual page 27

Ductable dual fuel indirect-fired heater
Hide thumbs Also See for Journeyman:
Table of Contents

Advertisement

Available languages

Available languages

Troubleshooting (cont.)
PROBLEM
Burner motor operates then shut off
Ignition occurs, then goes out
Main motor does not come ON after heating
heat exchanger.
Journeyman Ductable Dual Fuel Indirect-Fired Heater
Owner's Manual • Journeyman
SOLUTION
Check air pressure switch hose connection or kinks
Check air pressure switch for proper electrical
connections
Pressure switch hose must be be connected to the
positive (+) barb
Defective burner motor
Poor electrical connection or supply
Drawer assembly incorrectly position in burner tube
Low voltage
Check flame sensor connection
Check flame sensor location
Ground fault issue, poor ground
Flame sensor touching metal
Dirty ionization assembly
Low gas supply pressure
Main motor delay is NORMAL. Time will vary base on
ambient temperature.
Defective fan switch
Defective motor relay
Main motor wiring connection issue
Defective main motor
27

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ci360

Table of Contents