Safety Precautions - L.B. White Journeyman Owner's Manual

Ductable dual fuel indirect-fired heater
Hide thumbs Also See for Journeyman:
Table of Contents

Advertisement

Available languages

Available languages

6
Journeyman Ductable Dual Fuel Indirect-Fired Heater

Safety Precautions

■ Do not use this heater for heating human living quarters.
■ Do not use in unventilated areas.
■ Know the signs of CO and CO2 poisoning
- Headaches, stinging eyes.
- Dizziness, disorientation.
- Difficulty breathing, feeling of being suffocated.
■ Proper ventilation air exchange (OSHA 29 CFR 1926.57) to support combustions and maintain
acceptable air quality shall be provided in accordance with OSHA 29 CFR part 1926.154, ANSI A10.10
Safety Requirements for Temporary and Portable Space Heating Devices and Equipment used in the
Construction Industry or the Natural Gas and Propane Installation Codes CSA B149.1.
- Periodically monitor levels of CO, CO2, and NO2 existing at the construction site – at the
minimum at the start of the shift and after 4 hours.
- Provide ventilation air exchange, either natural or mechanical, as required to maintain
acceptable indoor air quality.
USA 8-Hr. Time weighted average
(OSHA 29 CFR 1926.55 App A)
CO
50 ppm
CO2
5,000 ppm
NO2
USA – Ceiling Limit
(Short Term Exposure Limit = 15 minutes)
CO
CO2
NO2
5 ppm
■ Ensure that the flow of combustion and ventilation air exchange cannot become obstructed.
■ As the building 'tightens up" during the construction phases, ventilation may need to be increased.
Owner's Manual • Journeyman
WARNING
Air Quality Hazard
Canada 8-Hr. Time weighted average
WorkSafe BC OHS Guidelines Part 5.1
and Ontario Workplaces Reg 833
25 ppm
5,000 ppm
3 ppm (Reg 833)
Canada STEL (15 minutes Reg 833/1 hr.
WSBC) WorkSafe BC OHS Guidelines part
5.1 and Ontario Workplaces Reg 833
100 ppm
15,000 ppm (WSBC)
30,000 ppm (Reg 833)
1.0 ppm (WorkSafeBC)