L.B. White Journeyman Owner's Manual page 13

Ductable dual fuel indirect-fired heater
Hide thumbs Also See for Journeyman:
Table of Contents

Advertisement

Available languages

Available languages

Journeyman Ductable Dual Fuel Indirect-Fired Heater
Inside Structure
WARNING
Asphyxiation Hazard
■ When installing indoors, the heater's exhaust
must be vented to the outside.
■ Failure to comply can result in asphyxiation
due to lack of adequate air supply or carbon
monoxide poisoning.
■ Carbon monoxide poisoning can lead to seri-
ous injury or death.
IN EXISTING CHIMNEY
1)
Anti-wind device, optional accessory
2) Horizontal crossing with minimal upside angle pitch of 5°
3) Chimney 8 in. x 8 in. of minimal inside measure
4) Chimney anti-explosion flap door
5) External seating wall
Note: The above information is a recommendation only.
Have you installation checked by a local authority.
Outside Structure
To prevent recirculation of flue gas from the exhaust
outlet to the heater air inlet, an exhaust stack of
2 ft. / 0.61 m minimum is required to be installed onto
the exhaust outlet. To protect against water entry
when the heater is installed outdoors, a rain cap is
necessary.
Optional accessory chimney and rain cap must be
purchased separately.
6 in. dia. exhaust pipe 500-30161
Rain cap, 6 in. 500-30162
■ When this heater is connected to a flue pipe, the
flue pipe shall terminate in a vertical section at least
two feet long and sufficient draft shall be created to
assure safe and proper operation of the heater. A
minimum draft of 0.20 in. w.c. is recommended.
■ Where back drafts may occur a vent cap should be
used on the exit from the flue pipe.
■ Horizontal runs of flue pipe should have a rise of 1
in 10 away from the heater.
DIRECTLY TO OUTSIDE
A. Minimal 3 ft. (0.91 m)
B. Minimal 2 ft. (0.61 m)
C. Shortest
D. The same or bigger than the
heaters stack outlet diameter.
E. Minimal 2 ft. (0.61 m)
Owner's Manual • Journeyman
WARNING
Asphyxiation Hazard
1
Rain Cap
Chimney
Exhaust Outlet
13
Supply
Air Inlet

Advertisement