Owner's Manual and Instructions
Tradesman 170 and Trademsan 170 Ultra Construction Heaters
Congratulations!
You have purchased the finest portable forced air construction heater available.
Your new L.B. White heater incorporates the benefits from the most experienced
manufacturer of heating products using state-of-the-art technology.
We, at L.B. White, thank you for your confidence in our products and
welcome any suggestions or comments you may have...call us, toll-free,
at (800) 345-7200.
ATTENTION ALL USERS
This heater has been tested and evaluated by C.S.A. International in accordance with
the requirements of Standard ANSI Z83.7 CSA 2.14 and is listed and approved as a
direct gas-fired forced-air construction heater with application for the temporary
heating of buildings under construction, alteration, or repair. If you are considering
using this product for any application other than its intended use, then please
contact your fuel gas supplier, or the L.B. White Co., Inc.
View this manual online at www.lbwhite.com
MODELS
OUTPUT (kW)
CP170
49.8
45.4
FUEL
Propane Vapor
Withdrawal
Natural Gas
Certification by:
150-29450

Advertisement

Table of Contents
loading

Summary of Contents for L.B. White Tradesman 170

  • Page 1 *Requires an app like QR Droid for Android or QR Reader for iPhone. We, at L.B. White, thank you for your confidence in our products and welcome any suggestions or comments you may have...call us, toll-free, at (800) 345-7200.
  • Page 2 Save this Owner’s Manual for future use and reference. ■ Owner’s Manuals and replacement labels are available at no charge. For assistance, contact L.B. White at 800-345-7200. WARNING ■ Proper gas supply pressure must be provided to the inlet of the heater.
  • Page 3: Table Of Contents

    Have your qualified installer review this manual with you so that you fully understand the heater and how it The L.B. White Co., Inc. has a policy of continuous product functions. improvement. It reserves the right to change specifications...
  • Page 4: Heater Specifications

    Heater Specifications Model CP170 SPECIFICATIONS Propane Natural Fuel Type Maximum / Minimum Input (kW) 49.8 /36.6 45.4/36.6 2.74 1.37 Burner Manifold Pressure (kPa) 2.76 3.36 nlet Gas Supply MAX. Pressure Acceptable at the Gas Connection of the 2.76 1.74 MIN. Heater (kPa) 3.56 kg 4.38 m3...
  • Page 5: Safety Precautions

    Safety Precautions WARNING Asphyxiation Hazard ■ ■ Do not use this heater for heating human living Improper combustion can lead to carbon monoxide quarters. poisoning leading to serious injury or death. Symptoms of carbon monoxide poisoning can include headaches, ■ Do not use in unventilated areas.
  • Page 6 14. This heater is equipped with a three-prong (grounding) plug for your protection against shock hazard and must 2. All installations and applications of L.B. White heaters be plugged directly into a properly grounded three- must meet all relevant local, state and national codes.
  • Page 7: Installation And Assembly Instructions

    Installation and Assembly Instructions GENERAL 8. Check all connections for gas leaks using approved WARNING gas leak detectors. Gas leak testing is performed as follows: Fire and Explosion Hazard Can cause property damage, severe injury or death WARNING Fire and Explosion Hazard To avoid dangerous accumulation of fuel gas, turn ■...
  • Page 8: Propane Gas Supply Sizing

    Contact If you are in doubt, contact the L.B. White Co., Inc. your fuel gas supplier if you have any questions. 14. The heater must be installed so as not to interfere 18.
  • Page 9: Hose And Regulator Assembly

    HOSE AND REGULATOR ASSEMBLY Propane Gas 1. Connect rigid end of hose to regulator and tighten 2. Install hose adapter to gas inlet of heater. Tighten securely. adpater securely. Connect end of hose with nut to hose adapter. Tighten hose nut securely. See Fig 3. FIG.
  • Page 10: Height Adjustment

    HEIGHT ADJUSTMENT This heater includes a height adjustment feature, FIG. 6 allowing the user to change the elevation of the heater for greater heat direction. See Fig. 6 for location of adjustment on front base of heater. KNOB To adjust the heater’s nose height: -- Loosen knob -- Lift heater slightly at blower outlet end -- Pull leg to desired setting...
  • Page 11: Start-Up Instructions

    Start-Up Instructions ■ 1. Connect the heater’s electrical cord to an approved It is normal for air to be trapped in gas hose on new electrical outlet. installations. You may need to recycle the heater before air is finally purged from the line and ignition Open the gas supply valve.
  • Page 12: Cleaning Instructions

    L.B. White Co., Inc. Dataplates, start- up and shut-down instructions and warnings are 4. Regulators can wear out and function improperly.
  • Page 13: Service Instructions

    Service Instructions GENERAL 4. Remove the fan guard and motor/fan assembly for WARNING access to barrel components. Burn Hazard ■ Heater surfaces are hot for a period of time after the 5. The auto reset backflash, and thermostat can be heater has been shut down.
  • Page 14: Backflash Switch

    AUTO RESET LIMIT SWITCHES There are two auto reset limit switches on this heater. FIG. 11 One is located on the burner plate. The other is located on the underside of the combustion chamber. Either will cut off power to the gas control valve if the heater should overheat.
  • Page 15: Igniter

    IGNITER MAINTENANCE REMOVAL Disconnect the ignitIon cable from the igniter. See 1. Using a small wire brush, reach down the barrel of Fig.16. the heater and brush the igniter electrode. Remove any build up. FIG. 16 Periodically check the gap. Gap should be 4.8 mm as shown in Fig.
  • Page 16: Thermostat

    THERMOSTAT Remove knob and thermostat mounting screws. See FIG. 20 Fig. 19. Remove the base bottom from the heater. 3.. Slide the thermostat sensing bulb from the cable tie at the wiring harness. See Fig. 20. FIG. 19 BULB THERMOSTAT SCREWS IGNITION CONTROL 1.
  • Page 17: Gas Pressure Checks

    GAS PRESSURE CHECKS ■ The following explains a typical procedure to be followed 3. Position the heater upright. Lower the height in checking gas pressures. adjustment leg to elevate the heater and prevent pinching of gauge hose See Fig. 24. ■...
  • Page 18: Troubleshooting Information

    Troubleshooting Information READ THIS ENTIRE SECTION BEFORE BEGINNING Tradesman Non - Diagnostic Heters Page TO TROUBLESHOOT PROBLEMS. Fan Does Not Run, Heater Does Not Light... . 22 Heater Lights, But Does Not Stay Lit ....22 Fan Runs, Heater Does Not Light .
  • Page 24: Electrical Connection And Ladder Diagrams

    Electrical Connection and Ladder Diagrams TRADESMAN 170 ULTRA TRADESMAN 170 CAUTION - REFER TO THE HEATER'S ELECTRICAL CONNECTION DIAGRAM WHEN SERVICING TO AVOID WIRING ERRORS & HEATER MALFUNCTION. CHECK FOR PROPER OPERATION AFTER SERVICING. WARNING: THIS HEATER MAY START AT ANY TIME...
  • Page 25: Heater Component Function

    Heater Component Function Air Proving Switch Gas Control Solenoid Valve Safety device used to insure that the proper air flow is being House an electromagnet which is energized by voltage and achieved before the gas valve is opened. opens to allow passage of gas to the burner orifice. Auto Reset Limit Switch Gas Hose Safety device wired into the control system which is used to...
  • Page 26: Parts Identification

    Parts Identification PARTS SCHEMATIC...
  • Page 27: Parts List

    PARTS LIST Part Number Tradesman 170 Tradesman 170 Item Description ULTRA Regulator with POL (Propane Gas) 28276 Regulator (Natural Gas) 29680 Hose, Fixed X Swivel, 9.5 mm ID x 5.2 m (Propane gas ) 22278 Hose, Fixed X Swivel, 12.7 mm x ID x 5.2 m (Natural gas) Accessory 22538 Adaptor, Hose, 3/8 in.
  • Page 28: Warranty Policy

    Warranty Policy HEATER L.B. White Co., Inc. warrants that the component parts of its Registering your product online with L.B.White will heater are free from defects in material and workmanship, automatically qualify a unit and its component parts for when properly installed, operated, and maintained in warranty consideration.
  • Page 29 *Exige une application telle que QR Droid pour Android ou appareils de chauffage. QR Reader pour iPhone. L.B. White, tient à vous remercier de la confiance que vous lui témoignez et vous invite à lui communiquer tout commentaire ou suggestion, sans-frais, au (800) 345-7200 ATTENTION À...
  • Page 30 ■ Les manuels de l’utilisateur et les étiquettes de remplacement sont offerts gratuitement. Veuillez contacter votre détaillant ou L.B. White Co. Inc. au (800) 345-7200 ATTENTION! ■ L’arrivée de gaz de l’appareil doit êtrre alimenté par une pression de gaz adéquate.
  • Page 31 Veuillez communiquer avec votre détaillant local de produits que son numéro de série. Vous trouverez cette information L.B.White ou avec L.B. White directement pour toute sur la fiche signalétique de l’appareil. interrogation ou assistance au sujet de cet appareil et son fonctionnement.
  • Page 32 Spécifications de l’appareil Modèle SPÉCIFICATIONS CP170 Type de combustible Propane Naturel Puissance maximum/minimum (kW) 49,8/36,6 45,4/36,6 2,74 1,37 Pression du manifold du brûleur (kPa) 2,76 3,36 Pression de MAX. l’alimentation en gaz acceptable à la prise 2,76 1,74 MIN. d’entrée de l’appareil.(kPa) 4,38 m 3 MAX.
  • Page 33 Consignes de sécurité ATTENTION Risque d'asphyxie ■ ■ Ne pas utiliser cet appareil pour le chauffage d'un Une combustion inadéquate peut entrainer des logement habité, garages, ateliers, ou autres espaces blessures sérieuses ou la mor t suite à un confinés.. empoisonnement au monoxyde de carbone.
  • Page 34 9. L’assemblage du boyau doit être inspecté 2. L’utilisation et l’installation des appareils de visuellement sur une base quotidienne, avant chauffage de L.B. White doit en tout temps répondre l’utilisation, lors d’un fonctionnement continu, ou aux normes et règlementations en vigueur aux après avoir déplacé...
  • Page 35 utiliser l’appareil. Le boyau d’alimentation en gaz doit 15. Lorsque le système d’alimentation en propane est un être à l’abri d’accumulation de débris de construction réservoir de type bonbonne, la taille minimale du ainsi que de surfaces très chaudes. L’assemblage du réservoir de propane à...
  • Page 36 Le test de présence de fuite de gaz se déroule ainsi : 1. Lire toutes les consignes de sécurité et suivre les recommandations de L.B. White lors de l’installation ATTENTION de votre appareil de chauffage. Si, au cours de Risques d’incendie ou d’explosion...
  • Page 37 à un soutirage de propane liquide. En cas d’interrogations, consulter L.B. White Co. Inc. ÉVALUATION DE LA QUANTITÉ DE GAZ PROPANE La vaporisation du propane est attribuable à de nombreux Malgré...
  • Page 38 ASSEMBLAGE DU BOYAU ET DU DETENDEUR Gaz Propane 1. Brancher la partie rigide du boyau au détendeur et 2. Fixer l’adapteur de boyau à la prise d’entrée du gaz serrer fermement. de l’appareil. Brancher le bout du boyau à l’adapteur à...
  • Page 39 AJUSTEMENT DE LA HAUTEUR L’appareil de chauffage comprend un dispositif FIG. 6 d’ajustement de la hauteur, ce qui permet à l’utilisateur de modifier l’élévation de l’appareil pour permettre un meilleur contrôle de la direction de la BOUTON chaleur. Consulter la figure 6 pour connaître l’emplacement du dispositif d’ajustement.
  • Page 40 Instructions de mise en marche ■ 1. Brancher le cordon électrique dans une prise de Il est normal que de l’air soit emprisonné dans le boyau courant homologuée. à gaz d’un système nouvellement installé. Il se peut qu’il soit nécessaire de lancer la procédure d’allumage 2.
  • Page 41 S’assurer qu’aucune n’est déchirée ou excessive vers l’appareil. endommagé. Contactez L.B. White pour remplacer toute étiquette endommagée. Les étiquettes des 4. Les détendeurs peuvent s’user et fonctionner moins mises en garde ainsi que celles por tant sur bien avec le temps.
  • Page 42 Directives d’entretien et de service GENERALITES et le thermostat peuvent être testés en effectuant une ATTENTION connexion temporaire de contournement hors du Risques de brûlures circuit : -- Rétablir le courant électrique vers l’appareil et ■ La surface entière de l’appareil demeure très chaude ouvrir les valves de gaz.
  • Page 43 INTERRUPTEUR DE LIMITES SUPERIEURES Il y a deux commutateurs auto de limite de réglant sur FIG. 11 cet appareil de chauffage. L'un est localisé sur la plaque de brûleur. L'autre est localisé sur le dessous de la chambre de combustion. Ou coupera le pouvoir à la soupape de contrôle de gaz si l'appareil de chauffage devrait surchauffer.
  • Page 44 ALLUMEUR DIRECTIVES DE ENTRENTIEN ENLEVEMENT Débrancher le fil électrique alimentant l’allumeur. Utiliser une petite brosse métallique, une portée en Voir Fig. 16. bas le baril de l'appareil de chauffage et brosse l'électrode d'igniter. N'impor te enlever lequel FIG. 16 développe. 2.
  • Page 45 THERMOSTAT 1. Retirer le bouton d’ajustement et les vis de montage. FIG. 20 Voir Fig. 19. 2. Enlever la base de l'appareil de chauffage. 3.. Glisser le thermostat qui sent l'ampoule de l'attache de câble au harnais d'installation électrique. Voir Fig.20.
  • Page 46 VERIFICATION DE LA PRESSION DE GAZ ■ Ce qui suit, décrit les procédures habituelles à respecter au 3. Disposer l'appareil de chauffage de retour sur sa base. moment d’effectuer une vérification de la pression de gaz. Abaisser la jambe d'ajustement de hauteur pour élever l'appareil de chauffage et empêche pincer du tuyau de ■...
  • Page 47 Guide de dépannage Les diagrammes de résolution de problèmes permettent de IL FAUT LIRE CETTE TOUTE CETTE SECTION AVANT DE COMMANCER UNE PROCEDURE DE DEPANNAGE. régler les problèmes courants. Il est impor tant de comprendre la nature du problème détecté afin de bien utilisé...
  • Page 48 SÉQUENCE DE DÉFAILLANCE D’ALLUMAGE: - La tentative d’allumage dure environ dix (10) secondes. - Si le module de contrôle d’allumage ne détecte pas une flamme pendant la séquence de tentatives d’allumage, le module passe en mode vérouillage de sécurité (le voyant lumineux émet trois clignotements).
  • Page 56 Diagramme des circuits électriques et diagramme en escalier TRADESMAN 170 TRADESMAN 170 ULTRA CAUTION - REFER TO THE HEATER'S ELECTRICAL CONNECTION DIAGRAM WHEN SERVICING MISE EN GARDE: Pendant une intervention de service ou d'entretien, toujours consulter le schéma de connexions électriques afin d'éviter MISE EN GARDE: Pendant une intervention de service ou d'entretien, toujours consulter le schéma de connexions électriques afin d'éviter...
  • Page 57 Fonction des composantes de l’appareil de chauffage Obturateur d’air Ligne d’alimentation en gaz Dispositif de sécurité utilisé pour réguler adéquatement Boyau flexible servant à acheminer le gaz de la source l’afflux d’air avant l’ouverture de la valve de gaz. d’alimentation principale ou d’un réservoir jusqu’à l’appareil.
  • Page 58 Identification des composantes ILLUSTRATION DES COMPOSANTES...
  • Page 59 LISTE DES PIÈCES Numéro de pièce Tradesman 170 Tradesman 170 Item Description ULTRA Régulateur avec P .O.L. (Gaz propane) 28276 Régulateur (Gaz naturel) 29680 Boyau, rigide et pivotant, 9.5 mm. × 4.57 m., Gaz Propane 22278 Boyau, rigide et pivotant, 12.7 mm. × 4.57 m., Gaz Naturel (Accessoire) 22538...
  • Page 60 Si entretenus selon les directives d'installation et d'entretien, un produit n'a pas été enregistré chez L.B. White, une copie ainsi que des consignes de sécurité émises et des du contrat de vente sera requise afin qu'un produit soit étiquettes et fiches fournies avec chaque appareil.

This manual is also suitable for:

Tradesman 170 ultra

Table of Contents