Ceiling Mounting Specifications - Epson GX Series Manual

Industrial robot:
Table of Contents

Advertisement

Industrial Robot: SCARA Robots GX series Manual

4.3.7.4 Ceiling Mounting Specifications

WARNING
Be sure to use four or more people when installing or relocating a model with ceiling mounting specifications,
and use three or more people when lifting a Manipulator. The Manipulator weights are as follows. Be careful
not to get hands or feet caught or have equipment damaged due to dropping of the Manipulator.
GX10-B65**R: Approx.46 kg (102 lbs)
GX10-B85**R, GX20-B85**R: Approx.49 kg (108 lbs)
GX20-BA0**R: Approx.50 kg (111 lbs)
When removing the Manipulator from a ceiling surface or other location, be sure to support the Manipulator
before removing the anchor bolts. Removing the anchor bolts without supporting the Manipulator is extremely
hazardous and may cause the Manipulator to fall.
1. Turn off all power, and remove the wiring and tubes connected to the Manipulator.
POINTS
If using variable mechanical stops for Joints #1 and #2 and the operating angle is limited, change to the
mechanical stop positions at factory shipping.
Setting the Work Envelope by Mechanical Stops
2. Wrap a sheet around the arm so that it will not get damaged. Secure the arm while referring to the figure.
Example of securing arm in place
Rev.7