Arm Movement Method In The Emergency Stop State - Epson GX Series Manual

Industrial robot:
Table of Contents

Advertisement

Industrial Robot: SCARA Robots GX series Manual
When the safeguard is opened, Protective Stop operates to change to the safeguard open state (display: SO).
Safeguard open
Operations are prohibited. Further robot operation is not possible until either the safeguard is closed, the latched state is
released, and a command is executed, or the TEACH or TEST operation mode is turned on and the enable circuit is
activated.
Safeguard closed
The robot can operate automatically in an unrestricted (high power) state.
WARNING
If a third party accidentally releases the safeguard while an operator is working inside the safety barriers, this
may result in a hazardous situation. To protect the operator working inside the safety barriers, implement
measures to lock out or tag out the latch release switch.
To protect operators working near the robot, be sure to connect a safeguard switch and make sure that it
works properly.
Installing safety barriers
When installing safety barriers within the maximum range of the Manipulator, combine safety functions such as SLP. Carefully
take into account the size of the hand and the workpieces to be held so that no interference occurs between the operating parts
and the safety barriers.
Installing safeguards
Design the safeguards so that they satisfy the following requirements:
When using a key switch type safety device, use a switch that forcibly opens the interlock contacts. Do not use switches
that open their contacts using the spring force of the interlock.
When using an interlock mechanism, do not disable the interlock mechanism.
Considering the stopping distance
During operation, the Manipulator cannot stop immediately even if the safeguard is opened. Also, the stopping time and
movement distance vary depending on the following factors.
Hand weight, WEIGHT setting, ACCEL setting, workpiece weight, SPEED setting, movement posture, etc.
For the stopping time and movement distance of the Manipulator, refer to the following section.
Appendix C: Stopping Time and Stopping Distance When Safeguard is Open
Precautions for safeguard operation
Do not open the safeguard unnecessarily while the motor is energized. Frequent safeguard inputs will reduce the life of the
relay.
Normal relay lifespan: About 20,000 times

4.1.6 Arm Movement Method in the Emergency Stop State

In the emergency stop state, move the Manipulator joints directly by hand as shown below.
Joint #1:
Push Arm #1 by hand.
Joint #2:
Push Arm #2 by hand.
Joint #3:
The joint cannot be moved up or down by hand because the electromagnetic brake is activated.
Move the joint while pressing down the brake release switch.