Danfoss iC7 Series Operating Manual page 55

Functional extension options
Hide thumbs Also See for iC7 Series:
Table of Contents

Advertisement

Functional Extension Options
Operating Guide
Selection number
6
7
10
11
12
7.6.2.2 Input T3 (Menu Index 9.4.2)
P 9.4.2.1 T3 Terminal Mode
Description: Select the mode for the terminal.
Default Value: 0 [Inactive]
Unit: -
The following are the selections for the parameter
Selection number
0
6
7
P 9.4.2.2 T3 Terminal Type
Description: Select the type of the terminal. If voltage is selected, the unit is V. If current is selected, the unit is mA.
Default Value: 1 [Voltage]
Unit: -
The following are the selections for the parameter:
Selection number
1
2
P 9.4.2.3 T3 Minimum Value
Description: Set the voltage or current representing 0% of the signal.
Default Value: 0
Unit: -
P 9.4.2.4 T3 Maximum Value
Description: Set the voltage or current representing 100% of the signal.
Default Value: 10
Unit: -
P 9.4.2.5 T3 Filter Time
Description: Set the filter time for the terminal.
Danfoss A/S © 2023.06
Parameter Type: Selection
Data Type: UINT
Parameter Type: Selection
Data Type: UINT
Parameter Type: Range (-20 — 20)
Data Type: REAL
Parameter Type: Range (-20 — 20)
Data Type: REAL
Selection name
Ni1000Tk6180
KTY84-1x0
KTY81/82-1x0
KTY81/82-121
KTY81/82-122
Parameter Number: 4925
Access Type: Read/Write
Selection name
Inactive
Analog Input
Temperature input
Parameter Number: 4926
Access Type: Read/Write
Selection name
Voltage
Current
Parameter Number: 4927
Access Type: Read/Write
Parameter Number: 4928
Access Type: Read/Write
AQ390830267692en-000601 / 136R0273 | 55
General Purpose I/O Installation
and Configuration

Advertisement